background image

Model PT502

Model PT503

Model PT504

• Press the ON/OFF button once
• The bottom LED comes on
• You can select your comfort 

temperature by pressing the ON/OFF 
button the desired number of times 
so that the required LED is lit.

• When you have selected the required 

setting and the desired temperature 
has been attained – the HEAT LED 
will turn red after one minute. 

• You can move from the top to the 

bottom LED by pressing the ON/OFF 
button twice. 

• When the thermostat is turned off, 

the desired temperature setting will 
be saved and will come on when the 
thermostat is turned on again

Method of Operation

To set 2 hour/4 hour/ 6 hour mode
Press the On/Off button until the 2 
hour LED light comes on. 
Press the On/Off button three 
times and the 4 hour LED light will 
come on. 
Then press the On/Off button 
three times and the 6 hour LED 
light will come on. 

To set manual mode 

Press the On/Off button and hold 
for 5 seconds. The Power and Man 
lights will come on.
NB: The Power LED will be lit up 
when the heating is on

.

To set Manual mode

Press the Power button and one of the green 
LED lights (P1, P2 or P3) will flash on/off once.
Then press & hold the Power button for approx 5 
secs and the manual and heat LED’s will light 
up. 
The controller will now operate in manual mode 
controlled by a preset comfort level setting. 

To turn off Manual mode 

Press the Power button once. The green LED 
which remains on is the programme mode which 
is now operating (P1, P2 or P3).

To completely turn off the heating

Wait until only one green LED is on – then press 
the Power button once. 

To set Programme mode  

Establish desired start time of heating.
Add 12 hours onto this time and this is when you 
programme the Timer (Refer to the Twelve Hour 
Set Back Table).
Press the Power button and one of the green 
LED’s P1, P2 or P3 will flash on/off once.
Press & hold the Power button for approx 5 secs 
and the manual and heat LED’s will light up. Do 
not release but continue to push the Power 
button and the unit will scroll through Manual, 
P1, P2 & P3 and then all LED’s will turn off. 
Release the Power button. 
The start time for P1, P2 & P3 are now 
programmed. To select the desired programme 
(P1, P2 or P3) press the Power button once to 
turn off Programme mode. 
Press the Power button once to turn on 
programme mode, before the green LED flashes, 
you must quickly press the Power button 
repeatedly to scroll through P1, P2 and P3. Stop 
pressing when the desired Green LED for P1, P2 
or P3 is lit. To change the Programme mode 
from P1 to P3(for example) you must repeat this 
entire step.
To turn off Programme mode, press the Power 
button once.
NB: The Heat LED will be lit up when the heating 
is on.

WARMUP NEW ZEALAND LTD - TWO(2) YEAR WARRANTY

This product is warranted against defects in material and workmanship under normal conditions of use for a period of two (2) years from the date
of purchase. During this period, Warmup will repair or replace the product if it is defective in normal operating conditions in terms of materials
or workmanship with a new product of equivalent quality at Warmup's option. This warranty is intended to give you the protection given to you
as a consumer under the Consumer Guarantees Act 1993. The warranty does not cover costs of transportation, removal, installation or damage
caused by misuse or accident. In no event will Warmup be liable for consequential loss resulting from the installation of the product. Any
defective product should be sent with the original invoice to the original installer, or shipped prepaid, insured and addressed to:

WARMUP NEW

ZEALAND LTD.

Copsey Business Park, 2/20 Copsey Place, Avondale, Auckland

Control Module Installation

Warranty

Phase (red)        
Element (brown)                   
Neutral (black)

Before wiring ensure that:
•All electrical connections are performed by a registered electrician only, as required by law.
•The supply is disconnected at the distribution board
•All connections are secure and tested prior to activation
•You have studied and fully understood the connection diagram. 
•Ensure the floor probe is connected & the sensor select switch is set to external (EXT) position.