background image

Installation Instructions

 

MTC-1991-WU Electronic Thermostat

 

 

Temperature Setting

 

The thermostat has a scale range of 10-50⁰C. To assist 
this  adjustment,  the  thermostat  has  a  LED  which  will 
glow  RED  when  the  heating  is  ON.  The  thermostat 
should  be  set  to  the  maximum  temperature  setting 
until  the  desired  temperature  of  the  room  or  floor  is 
achieved.  The  control  knob  should  then  be  turned 
back until the LED goes out. Fine adjustments can be 
made  over  the  next  few  days  to  suit  individual 
requirements.  
 

Max/Min Temperature Setting

 

Behind  the  knob  there  are red  and blue  locking rings 
held  in  position  by  a  screw.  To  set  the  limitations, 
loosen  the  screw  (C)  and  adjust  the  red  limit  ring  to 
the desired maximum, set the blue ring to the desired 
minimum temperature, then retighten the screw, The 
knob must be re-installed exactly as it was removed.  
 

Warning

 

The system must not be energized unless the system 
is  installed  according  to  the  instructions  and  the 
installation  meets  all  applicable  codes.  Warranty  is 
void  if  not  installed  according  to  this  instruction 
manual and proper procedure.  

 

Caution:  Disconnect  all  electrical  power  prior  to 
installing or servicing this unit.  
 
Error Detection 
The MTC-1991-WU has built-in error detection which 
will    de-energize  the  heating  circuit  if  the  sensor  is 
damaged  or  if  it  detects  an  open  or  shorted  sensor 
circuit. 

 

 

Technical data

 

Power supply: 

230-240V AC 

±

10%, 50Hz 

Output relay, SPST (resistive load): 

16A 

Built-in switch: 

2 pole, 16A  

Ambient operating temperature: 

0-50⁰C 

Scale limitation: 

minimum and maximum 

Scale range: 

10-50⁰C 

Temperature setback: 

not available 

On/Off differential: 

0.4⁰C 

Enclosure: 

IP20 

Dimensions: 

115mm(h) x 84mm(w) x 50mm(d) 

 

 
 

On/Off 
I – On O – Off 
 
Temperature  
setting 
10 – 50⁰C 
 
Indicator 
The light is red  
when the heat is  
On. 

MTC-1991-WU

– this electronic thermostat is mounted 

in  a  standard  flush  box.  The  red  LED  shows  that  the 
heat is ON. An ON/OFF selector switch on the front of 
the  cover  makes  system  operation  extremely  simple. 
This 

thermostat 

with 

remote 

sensor 

is 

recommended for the control of floor heating systems 
and  is  designed  to  meet  the  standard  requirements 
for  comfort,  safety  and  energy  saving  when  using 
electric radiant floor heating. 
 

Mounting of Floor Sensor

 

The  floor  sensor  should  be  placed  in  between  two 
runs of heating wire. Make sure it is centred so as to 
achieve  the best  accuracy. Make  sure  the  position  of 
this  sensor  is  in  an  area  of  the  floor  that  will  not  be 
covered  over  with  any  items  that  will  cause  a  heat 
build  up  which  could  result  in  the  overall  floor 
temperature being affected i.e. washing baskets, rugs 
etc. 
 

Thermostat installation 

This should be done by a registered electrician ONLY. 
The thermostat is to be mounted on a wall so that it is 
easily  accessible.  The  floor  sensor  should  not  be 
influenced by any other heating sources (i.e. the sun). 
• Remove  the  thermostat  knob,  noting  the  position 

• Loosen screw to remove frame and cover B 
• Attach  wiring  from  the  rear  of  the  thermostat 

according to the wiring diagram.  

• The  thermostat  is  mounted  in  a  standard  single 

gang electrical box. Please ensure that the adaptor 
plate is properly clipped on the thermostat.  

Re-install frame and cover 
Re-install the knob in the proper position 
 

Operation Manual 

 

 

Reviews: