The knoekt wireless Boiler Switch provides interlock for:
  • UFH demand

  • Radiator demand

  • DHW scheduling

  • Heating and Cooling changeover

  • Dehumidification demand
Where more than 2 channels are required multiple switches can be used.

(A)

  

System button (Pairing button and LED) 

(B)

  

Cover

(C & D)

 Supply Live and Neutral  terminals (230 V AC / 50 Hz, 6A)

(E)

  

PE terminals

(F)

  

Switching channel 

OUT1

 (N.O contact) 

(G)

  

Switching channel 

OUT2

 (change-over contact)

3 Function and device overview

A

B

PE PE

L

L

N N

1

1

L

2

L

C

D

F

E

G

A

B

PE PE

L

L

N N

1

1

L

2

L

C

D

F

E

G

Device overview: 

The Boiler Switch is part of the Warmup konekt Wireless System. Devices in 

the konekt Wireless System system can be easily paired and setup through 

the konekt Wireless Smart Hub using the konekt App. All functions of the 

konekt Wireless System are described in detail in the User Guide. The User 

Guide and Online manuals for all other konekt Wireless devices are available 

on www.warmup.co.uk

4 General system information

Summary of Contents for konekt WIRELESS KW-BLR2CH

Page 1: ...konekt W I R E L E S S BY Installation and operating manual Warmup konekt Wireless Boiler 2 Channel Switch KW BLR2CH ...

Page 2: ...2 Quantity Description 1 Warmup konekt Wireless Boiler 2 Channel Switch 4 Screws 3 0 x 30 mm 4 Wall Plugs 5 mm 1 Quick Start Guide Package Contents ...

Page 3: ...or Only Rads 7 6 2 2 Connect UFH with Rads or DHW 8 6 2 3 Connect Rads DHW 8 6 2 4 Connect air dehumidifier 9 6 3 Pairing the device to the Smart Hub 10 7 Troubleshooting 10 7 1 Command not confirmed 10 7 2 Duty cycle 11 7 3 Error codes and flashing sequences 11 8 Restore factory settings 12 9 Maintenance and cleaning 12 10 General information about radio operation 12 11 Technical specifications 1...

Page 4: ... prevent risk of electric shock the devices must be disconnected from the mains supply and discharged before conducting any works Safeguard against the supply being switched back on throughout works Non compliance with the installation instructions may result in a fire or an electric shock The device may only be used for fixed installations The devices must be securely attached within a fixed inst...

Page 5: ...Switching channel OUT2 change over contact 3 Function and device overview A B PE PE L L N N 1 1 L 2 L C D F E G A B PE PE L L N N 1 1 L 2 L C D F E G Device overview The Boiler Switch is part of the Warmup konekt Wireless System Devices in the konekt Wireless System system can be easily paired and setup through the konekt Wireless Smart Hub using the konekt App All functions of the konekt Wireless...

Page 6: ...orks Non compliance with the installation instructions may result in a fire or an electric shock The permitted cable diameter for all cable bushings are 8 to 11 mm You can flexibly mount the boiler switch for heating systems on walls using the supplied screws and plugs Use a pen to mark the four bore holes of the switch onto the wall where you plan to mount it Using a suitable drill make 4 x 5mm h...

Page 7: ... konekt wireless App The function of switching channel OUT1 F and if required switching channel OUT2 G will need to be assigned using the App Once paired to the Smart Hub you will be asked to assign this function See section 6 3 to pair the device to the Smart Hub UFH only assignment Rads only assignment OUT1 OUT1 Heating and cooling demand for floor heating actuators Heat demand for rooms ...

Page 8: ... OUT2 Hot water demand 230 V AC 50 Hz 6A Heat Source LR LS PE PE PE L L N N 1 1 L 2 L PE PE L L N N 1 1 L 2 L 6 2 2 Connect UFH with Rads or DHW Rads DHW assignment UFH with DHW assignment OUT1 OUT1 Heating and cooling demand for floor heating actuators Heating and cooling demand for floor heating actuators OUT2 OUT2 Heat demand for rooms Hot water demand ...

Page 9: ...9 230 V AC 50 Hz 6A PE PE L L N N 1 1 L 2 L Dehumidifier PE PE L L N N 1 1 L 2 L 6 2 4 Connect air dehumidifier Air dehumidifier assignment OUT1 Dehumidification for floor heating actuators ...

Page 10: ...ing mode Pairing mode will remain active for three minutes Your device will automatically appear in the konekt App To confirm scan the QR code attached to the device or alternatively enter the last four digits of the device number SGTIN in the App If pairing is successful the LED B will light up green If it lights red please try to pair the device again In the App select the functions of the boile...

Page 11: ...T If the duty cycle limit is exceeded the device may stop working for a brief period The device will start working normally again after a short period max 1 hour 7 2 Duty cycle 7 3 Error codes and flashing sequences Flashing sequences of the system LED A Flashing code Meaning Solution Short orange flashing Radio transmission attempting to transmit configuration data is transmitted Wait until the t...

Page 12: ...l information about radio operation Radio transmission is performed on a non exclusive RF channel which means that there is a possibility of interference occurring Interference can also be caused by switching operations electrical motors or defective electrical devices Warmup hereby declares that the Warmup konekt Wireless radio equipment is compliant with RED Directive 2014 53 EU and Radio Equipm...

Page 13: ...ng Capacity Switching Channel 1 Switching Channel 2 16 A 3680 W 5 A 1150 W Method of Operation 1 B Cycle Rating 10 000 Relay Changeover contact SPDT µ contact Normally open contact SPST μ contact Withstand Voltage 2500 V Radio frequency band 868 0 868 6 MHz 869 4 869 65 MHz Maximum radiated power 10 dBm Receiver category SRD category 2 Typ open area RF range 250 m Duty cycle 1 per h 10 per h Const...

Page 14: ... apply if it is shown by Warmup that the defect or malfunction was caused by failure to follow the instruction manuals incorrect installation or damage which occurred while the product was in the possession of a consumer Warmup s sole responsibility shall be to repair or replace the product within the terms stated above WARMUP SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND INCLUDING ANY IN...