Important Safety Instructions
–
Read all instructions before installing and using this heater.
•
The heater must be installed at least 1.8m above the floor.
•
There must be a minimum distance of 200mm between the heater and the ceiling.
•
The distance of your heater from the corners should be minimum 0.5m
•
Do not cover your heater and do not hang any clothing over the heater. Do not place any
clothing on or near the heater.
•
This heater is designed for use on a 230
–
240V AC supply.
•
Use this heater only as described in this manual. Any other use not recommended by the
manufacturer may cause fire, electric shock or injury to persons.
•
This heater is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they have
been given supervision or instruction concerning use of the appliance by a person
responsible for their safety.
•
Children should be supervised to ensure that they do not play with the appliance.
•
The fireguard of this heater is intended to prevent direct access to heating elements and
must be in place when the heater is in use.
•
The fireguard does not give full protection for young children and infirm persons.
•
This heater must be earthed. Connect to properly grounded outlets only.
•
Ensure both plug and socket is clean and free from dust when using.
•
To disconnect the heater from the power supply, turn the controls off, grip the plug and
pull from the power socket. Never pull by the cord.
•
Never touch the plug with wet or moist hands.
•
Do not use an extension cord with this heater unless connected via a RCD device.
•
Regularly inspect the power cord and plug for wear or damage. In order to avoid a
hazard, do not operate the heater with a damaged cord, plug or loose socket or after the
heater malfunctions or has been dropped or damaged in any manner.
•
Do not use the heater if the heating element is cracked or broken.
•
The heater must not be installed close to curtains and other combustible materials.
•
The heater must not be located immediately below or in front of a socket outlet.
Installation Instructions
•
The heater should be installed by a registered electrician if being hardwired.
•
Always disconnect the heater from the electricity supply and allow it to cool before
installation.
•
This heater can be mounted either horizontally or vertically.
•
The lowest part of the heater must be located at or above a minimum height of 1.8m
from ground level, so that the heater cannot be touched when in operation.
•
When mounting horizontally do not position the heater at an angle more than 90
⁰
and
less than 45
⁰
.
•
The supply cable must be at the lower end of the heater if the heater is installed at an
angle or vertically.
•
Keep the supply cord away from the body of the heater which will get hot during use.
•
Do not use the heater on a flammable surface.
•
Observe the minimum safe distance between the heater body and flammable surfaces
when mounting.
•
The heater should always have a minimum clearance of 200mm from a ceiling and
adjacent walls.
•
If the heater is to be used outside, a weatherproof outlet is recommended.