TESTING YOUR APPLIANCE LEAKAGE CURRENT 

INTERRUPTER (ALCI)

•  Test the ALCI periodically by pressing the white button while the 

Heater is in operation. This will cause the red button to pop up 
and disconnect the Heater from the power supply.

•  Reset the ALCI by pressing the red button to reconnect the Heater 

to the power supply.

•  If this test is unsuccessful, call WarmlyYours Technical Support 

for assistance at (800) 875-5285.

 

CONNECTION METHOD

The Under Desk Heater wall plug (

Diagram C

) has a built-in, ALCI  

plug connected to an 18AWG, SVT cable, 105°C power cord, with 
6A, 120 VAC rated in-line ON/OFF switch 

(Diagram B)

. The plug, 

cord and switch are UL listed components.

SAFETY RATINGS

• The system is water resistant and rated to IPX 7.
• The main electrical plug incorporates an ALCI for North America.
• Plug is UL and NEC (National Electrical Code) compliant.

4

DIAGRAM C

Summary of Contents for Under Desk Heater

Page 1: ...User Manual for WarmlyYours Under Desk Heater ...

Page 2: ...der Desk Heater mat Never use the Heater in bathrooms or other wet areas Never submerge the Under Desk Heater in water Never shampoo or steam clean the Heater Never use the Heater on stairways or steps Never drop or place heavy solid objects with a footprint of 6 x 6 or larger such as a filing cabinet or stereo equipment on top of the Heater Never staple or otherwise puncture the Heater with sharp...

Page 3: ...notice a slight odor when first using your Heater continue to use as instructed The odor will dissipate over time 5 Select the on position located on the rocker switch to turn the Under Desk Heater on 6 The mat will be warm to the touch within 5 minutes Allow approximately 30 minutes for your Heater to reach optimal temperature 7 Turn your Under Desk Heater off when not in use Note If the mat does...

Page 4: ...3 DIAGRAM A DIAGRAM B To Under Desk Heater RESET TEST WARNING TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE MODIFY OR IMMERSE THIS PLUG ON OFF ALCI RED WHITE ...

Page 5: ... this test is unsuccessful call WarmlyYours Technical Support for assistance at 800 875 5285 CONNECTION METHOD The Under Desk Heater wall plug Diagram C has a built in ALCI plug connected to an 18AWG SVT cable 105 C power cord with 6A 120 VAC rated in line ON OFF switch Diagram B The plug cord and switch are UL listed components SAFETY RATINGS The system is water resistant and rated to IPX 7 The m...

Page 6: ...hout receiving authorization Under this Limited Warranty WarmlyYours com Inc will provide the following remedy If the Product is determined to be defective in materials and workmanship and has not been damaged as a result of misuse misapplication or improper installation WarmlyYours com Inc will refund the original purchase price or replace the Product WARMLYYOURS COM INC DISCLAIMS ANY WARRANTY NO...

Reviews: