background image

5

CONTROLLING YOUR SYSTEM:

WarmlyYours recommends that the SmartStat 
programmable thermostat control the Environ II 
heaters. The SmartStat come with a fl oor sensor that 
allows you to set your heater to the exact temperature 
you desire. These sophisticated units also allow you 
to set the time  – for example one may chose to have 
a warm bedroom carpet fi rst thing in the morning upon 
waking, the carpet does not need to remain warm 
during the day, but can be programmed to come on 
again for a few hours around bedtime!

Most wood laminate manufacturers specify that their fl oors should not be 
subjected to temperatures in excess of 84 degF. The only reliable way to 
achieve this is to install a temperature sensor on top of, or directly under the 
Environ II panel, placed under the wood laminate.

 

Check with your laminate 

manufacturer or WarmlyYours to see what are their recommendations for 
installing electric radiant heat under their fl oors.

PROFESSIONAL ELECTRIC INSTALLATION:

Caution:

 Only a qualifi ed person who is familiar with the construction 

and operation of the apparatus and the hazards involved shall install this 
product.

The installation of electrical systems presents risks of fi re and electrical 
shock which can result in personal injury. Caution should always be taken 
to guard against each such risk. Only a qualifi ed electrician should connect 
Environ II panels to the thermostat and / or to the electrical supply circuit. All 
such connections MUST be in accordance with the National Electrical Code 
and all local Codes. A carpet layer, fl ooring contractor or a Do-It-Yourselfer 
can install the panels on the fl oor, before the electrician connects them to 
a thermostat and an electrical circuit.

For USA installations: All such connections MUST be in accordance with 
the National Electrical Code and all local Codes.
For Canadian installations: The installation shall be made according to 
the provisions of Section 12 and 62 of the Canadian Electric Code Part 1 

which reads: 

ITEMS REQUIRED FOR SYSTEM INSTALLATION:

 

System components from WarmlyYours

1.

  The customized installation Plan (or layout)

2.

   If multiple mats are to be connected to one control device 

they must be wired in parallel

3.  

Control with an in-fl oor temperature sensor.

Double Check your Dimensions

Check and verify that your plan has the correct room dimensions. Your 
order consists of the exact amount of material required to complete your 
project. If the measurements of your space have changed, this will affect 
how much product is required and how it will be installed. If you have 
any discrepancies or questions call WarmlyYours Customer service at 
800 875 5285.

Ground Fault Circuit Interrupter

GFCI or ‘GFCI-breaker’ indicating its capacity if not incorporated into the 
control device you are using. This is a built-in feature of the SmartStat 
Programmable Thermostat.

Digital Ohm Meter (multi-meter)

Test the foil mats before, during and after the installation. A digital meter 
is strongly recommended because of the precise measurements needed.

Electrical Housing Boxes/Switch Plates

All control devices except a Relay Contactor fi t into a single gang box. 
If a double gang box is used it will need to be fi tted with a single gang 
mud ring. We recommend a double gang box with a single gang mud 
ring as it provides more room to place all the wires. 

“Rule 2-022 Renovation of Existing Installations: The inspection 
department may require such changes as may be necessary to be 
made to existing installations where, though hard usage, wear and tear, 
or as a result of alterations or extensions, dangerous conditions have 
developed.”

Summary of Contents for ENVIRON II

Page 1: ...Installation Manual for your ENVIRON II Floor Heating System...

Page 2: ...one or similar hard floor coverings and MUST NOT be installed under nailed hardwood flooring Other products are available to heat these types of floor contact WarmlyYours com Inc for more information...

Page 3: ...NDER CARPET Before You Start Compatible Carpets Compatible Carpet Cushions Installing The Panels Installing The Thermostat Important Points For The Carpet Fitter Restrictions On Furniture Placement an...

Page 4: ...It is waterproof thus protecting all internal wiring and connections within the panel It is rigid yet still sufficiently flexible to make for ease of installation It does not ruck or buckle when carp...

Page 5: ...rcuit For USA installations All such connections MUST be in accordance with the National Electrical Code and all local Codes For Canadian installations The installation shall be made according to the...

Page 6: ...e placed over the panels More specific details are contained in the Restrictions on Furniture Placement sections later in this Installation Manual NO OTHER HEATERS UNDERNEATH Environ II panels must NO...

Page 7: ...n of the heater wire thereby allowing the electricity to flow to the ground through the foil sheet If this situation occurred it would immediately trip the GFCI Ground Fault Circuit Interrupter Howeve...

Page 8: ...is installed Beware of automatic staple guns if you use one to secure the cushion underlayment to the subfloor A badly installed staple that protrudes from the floor can pierce and destroy the Enviro...

Page 9: ...th adhesive tape as set out below Any adhesive tape will do After deciding the route that your power supply cables will take from the panel to the point of supply cut a 1 4 wide channel in the carpet...

Page 10: ...an one panel is connected to a thermostat ensure that the circuit connecting the thermostat to the house power is correctly rated for the total amperage of the combined heaters For the total amperage...

Page 11: ...footprint of 1 4 square inch ie x or less on the carpet irrespective of the weight of the furniture Never place any item with a footprint of 36 square inches ie 6 x 6 or more on the carpet if that ite...

Page 12: ...nd mat It is important to keep an accurate record of where the panels are installed to assist you and a future owner to easily locate them should you undertake remodelling work in the room at some fut...

Page 13: ...ensors must be used with all wood laminate installations as this is the only way to restrict the Environ II panel from exceeding the temperature specified by the wood laminate manufacturers In choosin...

Page 14: ...following restrictions and precautions Never pierce the wood laminate with sharp items such as knives pins tacks staples needles and the like Never drive nails or screws through the wood laminate to...

Page 15: ...Fault Interrupter 4 The installation is to comply with all national and local Electrical and Building Codes as well as any other applicable statutory requirements 5 The manufacturer hereby reserves hi...

Page 16: ...carpet with sharp objects d Turn off the heater when shampooing carpets or if any spillage occurs to eliminate undue shrinkage Do not turn on again until carpet underlay and heater are all dry e To p...

Reviews: