Note:
When the Base screw is removed, gas will leak from the out let, ensure that the pilot is not adjusted or the screw is removed
when the fire is burning.
•
Adjustment of Pilot - 3 Flame: unscrew base screw as shown in Diagram 2 .
•
Insert a screwdriver as shown in Diagram 3 and adjust the Adjustment screw up inside the 3 Flame Pilot to
adjust the Flame height .
•
The Flame must always be passing over the Electrodes &/or File Tube on either side.
•
Replace the Base screw and check for leaks.
ADJUSTMENT OF HI
—
LOW PRESSURE (SG ONLY) (Only to be Adjust-
ed by Gasfitter)
ADJUSTMENT OF THE PILOT - 3 FLAME (BOTH SG & EG) (Only to be Adjusted by
Gasfitter)
Adjustment of High & Low Settings Must be Carried out by a Certified Gas Fitter Only
.
3 Flame Pilot in
Assembled State
Correct Operation of
3 Flame Pilot
3
2
Note: to Gasfitters
The 3 flame pilot may need adjust-
ment after a period of running time
on set up, as the increase in heat
in the fire will induce a higher draft
in the fire, and may pull in flame
away from the File tube causing the
fire to shut down.
If a Solenoid is fitted to the SG Burner ensure the power switch at the wall is turned On to allow gas into the Burner .
Note* Control Valves are Factory Set but may require adjustment onsite.
Turn Appliance off & remove front plastic cover on Igniter, pull cover to slide off.
Unscrew test nipple on the Burner manifold & fit the test gauge securely - See Diagram.
* To Set the High: light the burner & turn to High - then adjust the High screw to the desired pressure -
See Spec’s.
* To Set the Low: Llight the burner & turn to Low - then adjust the Low screw to the desired pressure -
See Spec’s.
Extinguish Appliance, remove test equipment and secure test nipple.
* Check valve & burner for correct operation & check Fire for gas leaks.