8

 

FLUE DETAILS DIMENSIONS

 

Minimum Flue Height

 

  

Flue Height

 

3600

 

Measured From Top of Adaptor

 

B + 3600

 

NOTE: 

 

Ensure that a Standard Tested Warmington Flue System is used on Warmington Fires.

 

FLUE SYSTEM INSTALLATION GUIDE

 

 

Flue details

 

 

No:

 

SG / EG

 

700

 

SG / EG

 

780

 

SG / EG

 

900

 

SG / EG

 

1100

 

SG / EG 

600 

Gas Cowl

 

1

 

200

 

200

 

250

 

250

 

150

 

Flue Diameter

 

3

 

200

 

200

 

250

 

250

 

150

 

Liner Diameter

 

3

 

250

 

250

 

300

 

300

 

200

 

Spacer

 

3

 

200/250

 

200/250

 

250/300

 

300/300

 

150/200

 

Bottom Spacer

 

1

 

200/250

 

200/250

 

250/300

 

250/300

 

150/200

 

This is a general installation guide only –

 

Contact a 

NZHHA Installer

” 

or Gas Fitter for      

Installation Advice.

 

 

1.

 

Install the first length of flue pipe with the crimped end down, inside the Adaptor collar, ensure that the 

flue pipe is sealed into the collar with exhaust sealant. Rivet the flue in 3 places around the Adaptor collar. 

Place a bottom spacer around the flue pipe approximitaly150mm above the adaptor collar. Secure in posi-

tion by tightening the screw and nut.

 

2.

 

Install the second length of flue pipe with the crimped end down and fit by riveting in at least 3 places 

around the flue pipe joint. Ensure that the flue is sealed into position with sealant.

 

3.

 

Install the first section of flue pipe liner with the Crimped end up, over the flue pipe and over the spacer 

that is fixed to the flue pipe. This spacer will keep the liner concentric about the flue pipe.

 

4.

 

Position flue spacer at the flue pipe joint for every length of 

Flue pipe

” 

and 

Liner

”.

 

Repeat the Steps from 1 –

 4 

to the installed required height of the flue system. The flue system is to comply with 

the current standards.

 

 

IF FLASHING CONE NEEDED

 

 

 

1.

 

NOTE:

 The last length of flue pipe needs to extend past the liner so that when the 

top spider

” 

and the 

Flashing cone

” 

are fitted, that the 

flashing cone

” 

and the 

flue pipe

” 

are 

flush,

 or that the 

flue pipe

” 

is 

5mm lower

 that the 

Flashing cone

”.

 

2.

 

Fit the 

Top Spider

” 

into position, ensure that the legs of the spider are fitted inside the liner and that the 

spider is positioned hard down onto the liner and tighten with the screw and nut. 

 

3.

 

Place the 

Flashing cone

” 

over the 

flue pipe

” 

and press hard down onto the 

Top Spider

”. 

(Note that the 

Flue pipe

” 

and the 

Flashing Cone

” 

are either flush or the 

Flue pipe

” 

is 5mm Lower than the 

Flashing 

cone

”.) 

Ensure that the 

Flashing cone

” 

is clear for the venting from the 

Liner

” 

and the 

flue pipe

”.

 

4.

 

Fit the 

Cowl

” 

to the top of the flue pipe. The 

Cowl

”, “

Flashing cone

”, 

and the 

Flue pipe

” 

can be secured 

to each other with the uses of a stainless steel self tapping screw. This will allow the 

Cowl

” 

to be re-

moved for cleaning.

 

5.

 

Flue system may require Bird Proofing due to the installation and locations, discuss this with your install-

er for the best advice.

 

6.

 

If the Flue system is installed into a 

Chimney Chase

”, 

allow for air vent as close to the top of the chase 

as practical, or allow venting through the 

Chimney Chase Flashing

”. 

Venting Flashing cone

” 

and a 

25mm gap around the Liner with a 

Venting Flashing Cone

-

Spider

” 

can be used. Ref : to Figures 

……

in 

this specification.

 

 

 

 

a “the flue pipe shall extend not less than 4.6m above the top of the floor protector.”

 

 

b “ the minimum height 

of the flue system within 3 m distance from the highest point of the roof shall be 600mm 

above that point.”

 

 

c “the minimum height of the flue system further than 3 m from the highest point of the roof shall be 1000mm 
above the roof penetration.”

 

 

d “no part

 of any building lies in or above a circular area described by a horizontal radius of 3 m about the flue 

system exit.”

 

Summary of Contents for EG 700

Page 1: ...NZHHA SFAIT Installer in your area A licenced certified gas fitter and licenced electrician are required to run power and gas supplies as required to the unit and any commissioning as part of the ins...

Page 2: ...ical system to ensure that there is always a neutral or positive pressure at the fireplace and a negative pressure at the flue outlet This will ensure that the draft in the flue system is always to th...

Page 3: ...95 675 Insulation Kit Height G 620 620 620 620 620 Insulation Kit Depth H 485 485 485 485 485 Centre of Flue I 315 315 285 285 321 Flue J 200 200 250 250 150 Flue Liner K 250 250 300 300 200 Fascia Wi...

Page 4: ...rner Pressure Low kPa 0 75 0 75 0 75 0 75 0 75 MJ h 29 38 42 50 26 Flame Effect Output Only Effect Effect Effect Effect Effect Supply Pipe Size dia min 3 8 3 8 1 2 1 2 3 8 Natural Gas Nominal Pressure...

Page 5: ...Cell Clearance Depth Q 535 535 535 535 535 Hearth Width R 1100 1180 1300 1500 1000 Hearth Projection S 300 300 300 300 300 Chimney Chase Clearance T 350 350 400 400 300 Window Height V 660 660 660 66...

Page 6: ...G EG 1100 SG EG 600 Hearth Width R 1100 1180 1300 1500 1000 Hearth Projection S 300 300 300 300 300 Alcove Width O 810 895 1010 1210 690 Alcove Depth Q 535 535 535 535 535 Centre of Flue I 315 315 285...

Page 7: ...G 1100 SG EG 600 Heat cell Clearance Width OO 810 1210 1210 1210 690 Alcove Clearance Height PP 2400 2400 2400 2400 2400 Alcove Clearance Depth QQ 600 600 600 600 600 Window Height VV 630 630 630 630...

Page 8: ...to comply with the current standards IF FLASHING CONE NEEDED 1 NOTE The last length of flue pipe needs to extend past the liner so that when the top spider and the Flashing cone are fitted that the f...

Page 9: ...1041 20th July 2004 FLUE PENETRATION vented through alcove double lined flue system FLUE PENETRATION Vented through Top Flashing Note External requirements Refer to relevant standards Install flue sys...

Page 10: ...Y CHASE FLASHING AND AIR VENTILATION OPTIONS VENTING THROUGH CHIMNEY CHASE No Insulation under flashing VENTING THROUGH FLASHING Insulation under flashing Note Flashing spigot height is determined by...

Page 11: ...ange product specifications without prior notification All Dimension are in mm Copyright 11 FLUE HEIGHT MINIMUM DETAILS FRAME OUT AND TRIM OUT DETAILS FOR CHIMNEY CHASE The flue exit is to comply to r...

Page 12: ...LTD reserves the right to change product specifications without prior notification All Dimension are in mm Copyright 12 COMBUSTIBLE MANTLE CLEARANCES RAISED HEARTH CLEARANCES Note For Combustible Floo...

Page 13: ...GAS SUPPLY ELECTRONICS LOCATION Firebox SG EG 700 SG EG 780 SG EG 900 SG EG 1100 SG EG 600 From Base Of Firebox AA 86 86 86 86 86 From Centre Of Firebox BB 275 315 375 475 215 Plinth CONCEPT THROUGH...

Page 14: ...fied on the Data Plate is correct for the available supply LPG or NG A Copper Gas supply capable of supplying the correct MJ h should be brought into the rear of the Installation Cavity through the ho...

Page 15: ...coals onto the Vermiculite Base 2 Top Row Assemble 2 top rows of coals onto the bottom row Each coal randomly posi tioned with the torn roughest facing outward Ensure coal positioning does not directl...

Page 16: ...to light all the way across Once the flame is established adjust to the desired setting and close the cover To shut down Open the cover by pulling it outwards Turn the control ignition switch to PILOT...

Page 17: ...pressure see spec s Extinguish Appliance remove test equipment and secure test nipple Check valve burner for correct operation check fire for gas leaks Note When the base screw is removed gas will le...

Page 18: ...to observe the following precautions associated with any heating appliance or open fire Do not cover or restrict the fireplace upper or lower vents in any way as this may result in a build up of hazar...

Page 19: ...Copyright 19 Option 2 Three speed fan as additional option on SG units or EG units without remote controlled electronics eg units with on off hi low switches on the wall Option 1 Single speed fan as...

Page 20: ...urner will operate any pressure between the hi and the low pressures DIAGRAM B SHOWING CONTROL VALVE WITH TEST POINTS AND ADJUSTING SCREW After checking the pressure turn the unit off remove manometer...

Page 21: ...Due to continued product improvement Warmington Ind LTD reserves the right to change product specifications without prior notification All Dimension are in mm Copyright 21 EG ON OFF ONLY SIT840 valve...

Page 22: ...r river rocks to achieve their full flame pattern and glow During the initial burn period some smoke and smell may be experienced Because of this run the appliance on the high po sition in a well vent...

Page 23: ...Due to continued product improvement Warmington Ind LTD reserves the right to change product specifications without prior notification All Dimension are in mm Copyright 23 GAS STARTER SCHEMATIC DIAGRA...

Page 24: ...y Press and hold the or button for 2 seconds or longer to in crease or decrease the day of the week by 1 day every 0 5 seconds Press OK to complete setting The time and day of the week is now set SETT...

Page 25: ...WE TH FR MO TU WE TH FR SA SU SU SA MO TU WE TH FR SA SU To accept the selected day s of the week press OK First period s start time The display will indicate P1 on the top The Hour and AM PM setting...

Page 26: ...le com store apps details id com millec intelligythermostatmkii Or search for Intelligy Thermostat MKII in your smart phone app store For instructions on how to push the appliance to your Wi Fi please...

Page 27: ...first and once this is on it will ignite the main burner Pressing and releasing the power button again will switch off the appliance When the appliance is turned on the gas fire will be set to medium...

Page 28: ...s to pressure is to be carried out by a Certified Gasfitter If adjustments are necessary remove the cap The Pressure Adjustment screw and nut are on the front side of the Gas Control Valve shown in di...

Page 29: ...atisfied that the appliance is working correctly fit the front panel assembly back to the gas burner NOTE Ensure you peel the Protective Plastic Coating from any stainless steel components if fitted A...

Page 30: ...1 Due to continued product improvement Warmington Ind LTD reserves the right to change product specifications without prior notification All Dimension are in mm Copyright 30 FULLY MODULATING SIT 845 W...

Page 31: ...ate building codes This appliance must be serviced annually and any service operation must be carried out by a qualified service person WARNINGS WARNING ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT...

Reviews: