3
24 VOLT STANDARD ELECTRONIC
IGNITION SYSTEMS - High Capacity
Model # CFB290 NG/LP with 24VIKHC
Model # CFB300 NG/LP with 24VIKHC
Model # CFBL210 NG/LP with 24VIKHC
Model # CFBL250 NG/LP with 24VIKHC
Model # CFBL270 NG/LP with 24VIKHC
Model # CFBL320 NG/LP with 24VIKHC
Model # CFBH240 NG/LP with 24VIKHC
Model # CFBH260 NG/LP with 24VIKHC
Model # CFBH300 NG/LP with 24VIKHC
Model # CFBH340 NG/LP with 24VIKHC
Model # CFBH420 NG/LP with 24VIKHC
Model # CFBT230 NG/LP with 24VIKHC
Model # CFBT290 NG/LP with 24VIKHC
Model # CFBT350 NG/LP with 24VIKHC
24 VOLT PREMIUM ELECTRONIC
IGNITION SYSTEMS - Standard Capacity
Model # CFB60 NG/LP with P24VIKSCCG
Model # CFB120 NG/LP with P24VIKSCCG
Model # CFB180 NG/LP with P24VIKSCCG
Model # CFB290 NG/LP with P24VIKSCCG
Model # CFBL90 NG/LP with P24VIKSCCG
Model # CFBL110 NG/LP with P24VIKSCCG
Model # CFBL130 NG/LP with P24VIKSCCG
Model # CFBL150 NG/LP with P24VIKSCCG
Model # CFBL190 NG/LP with P24VIKSCCG
Model # CFBL210 NG/LP with P24VIKSCCG
Model # CFBL250 NG/LP with P24VIKSCCG
Model # CFBL270 NG/LP with P24VIKSCCG
Model # CFB60 2XL NG/LP with P24VIKSCCG
Model # CFBH120 NG/LP with P24VIKSCCG
Model # CFBH160 NG/LP with P24VIKSCCG
Model # CFBH200 NG/LP with P24VIKSCCG
Model # CFBH240 NG/LP with P24VIKSCCG
Model # CFBH260 NG/LP with P24VIKSCCG
Model # CFBT110 NG/LP with P24VIKSCCG
Model # CFBT170 NG/LP with P24VIKSCCG
Model # CFBT230 NG/LP with P24VIKSCCG
Model # CFBT290 NG/LP with P24VIKSCCG
24 VOLT PREMIUM ELECTRONIC
IGNITION SYSTEMS - High Capacity
Model # CFB300 NG/LP with P24VIKHCCG
Model # CFBL320 NG/LP with P24VIKHCCG
Model # CFBH300 NG/LP with P24VIKHCCG
Model # CFBH340 NG/LP with P24VIKHCCG
Model # CFBH420 NG/LP with P24VIKHCCG
Model # CFBT350 NG/LP with P24VIKHCCG
Model # CFBT410 NG/LP with P24VIKHCCG
Model # CFBT470 NG/LP with P24VIKHCCG
Aluminum
Plate/Pan
(G
1
)
(G
2
)
(D)
(E)
(F)
EM
ERGEN
CY
STOP
P U S H
0
5
10
15
30 25
20
55
50
45
35
40
4"
120"
Emergency Stop
Push Button
(Optional)
2 hr or 12 hr
Dial Timer
(Switch type
optional)
110V\120V
Power Line
(A)
Clearances
from combustible
materials needed
per manufacturer
recommendation
- 4" Minimum clearance
recommended for media
- 12 - 13" Minimum clearance
below plate required for
electronic ignition
(H)
Fire Pit Cavity Components
A - GFCI Outlet (by others)
B - Location for remote
receiver (Optional)
C - Pigtail plug included for
easy installation
D - Electronics Box (Houses
120V - 24V Transformer)
E - 24V Power From
Transformer to Gas Valve
F - Gas Valve / Control Box
G
1
- Wires to Pilot
G
2
- Gas to Pilot
H - Gas Valve Supply IN
I - Gas Stub from source
(by others)
CROSS
FIRE™
Brass Burner
Enclosure
constructed of all
non-combustible
materials
36"
(C)
10"
(I)
(B)
Recommended 18 sq.
inches of venting, or
equivalent, on
OPPOSING sides of fire
pit. (36 inches total)