VERTICAL ASSEMBLAGE OF RADIATORS:

 

  Radiators should be carried and assembled  

without being unpacked. The unpacked 

radiators must not be carried by being hold 

by custards aside.

3.  The stocking must be made in a ventilated 

and dry place without unpacking radiators.

4.  In the course of stocking, radiators must 

     be stacked by no more than 10 pieces.

5.  The maximum functioning pressure of 

radiators is 10 Bars. 

6.  Radiators are delivered with assemblage 

accessories: 3 stoppers, 1 drain and fixing 

pins with ankles and screw factories. These 

accessories must have to be assembled in 

accordance with the figure 1. The fixing pins 

must be fixed in order to guarantee stability 

and to support the weight of the filled 

radiator.

a) The Warmhaus Radiators have to be 

assembled by using the delivered fixing pins 

(see it in the Figure 1). 

b) The position of the fixing pins in comparison 

with the radiator is noted in the Figure 1.  The 

minimal distance between radiator and floor 

should not be less than 100 mm.

c)  Having drawn on the wall, the position of the 

fixing pins and of installed plugs, to take up 

the lower pins of the radiator. Assembly 

then, the top hanger brackets without 

tightening the screws.

7.  The warranty period is 10 years from the 

date of delivery.

ATTENTION THE POSITION OF THE LEGS OF 

FIXING MUST RESPECT COAST B OF THE FACE 

1 THERE.

d) After positioning of the radiator, tighten the 

top hanger brackets.

e) Assembly the stoppers after the chosen 

assemblage chosen as well as the air vent 

plugs which will be imperatively on the 

upper part of the radiator.

f)  Connect the feeding of the installation by 

taking care to allow these ones to dilate 

without putting pressure on the radiator.

ATTENTION !

•  This product is only conceived to be used a 

system of central heating  or a system of hot 

water tank of central heating, with a purpose 

to guarantee a residential heating or an 

individual heating.

•  The assemblage of this product must be made 

by a competent skilled person in this activity.

•  Control if the radiator which you received is a 

good model and, if it has good dimensions 

before unpacking.

•  Do not throw the packing before having 

proved that the small packet containing the 

linking and assemblage rooms is in your 

possession. 

•  We recommend you to take personal security 

measures in the course of radiator 

assemblage.

The necessary specifications of the water used in 

a radiator have to be:

a) pH: minimum 9,5 - maximum 11,5

b) Complete hardness: maximum 30 ppm 

CACO3

c)  An oil dumping device must be set up on 

heating circuit to have no air and oxygen 

presence in the radiator.

Hardness of the water used in the circuit of a 

central heating should not be higher than 

aforementioned value. If the hardness of the 

used water is higher than aforementioned value 

a corrective action or a treatment will have to be 

set up.

The deterioration of the radiator due to 

different problems of water cancels 

the guarantee.

1.  Do not unpack radiators in the course of 

construction work or renovation and as long 

as painting, coating or other jobs are finished. 

You can take radiators up, if necessary, 

without unpacking them. 

2.  Pay attention to the fact that the products are 

not thrown on the facedown, in the course of 

manipulation and assemblage. 

Reviews: