2.2. USE WITH ROOM THERMOSTAT (OPTIONAL)

This product can be used together with a room thermostat which can be 

purchased separately as an accessory. All Warmhaus thermostats can be 

connected with dual-wired cables. Carefully read user’s and installation 

instructions given in the Accessory set. When connected to a room 

thermostat, the appliance can be operated based on requested room 

temperature. With certain models of control units, you may run your boiler 

on a daily / weekly programme. 

General Utilisation Type 

•  Please consult our authorised services for room thermostats compatible 

with Warmhaus boilers.

•  Do not remove device components during operation.
•  Do not place the boiler in a position allowing direct sunlight exposure or 

near heat sources.

•  Manufacturer company shall not be responsible for below given 

situations:

 

a) Faulty installation

 

b) Making intervention on the device by unauthorised persons

  c) Failing to follow instructions given in this book and room thermostat 

booklets 

Installation instruction:

 Device installation shall only be performed by the 

Warmhaus Authorised Service. The dual cable required for installation is 

supplied by the dealer/consumer.

Maintenance and Service Life:

 Warmhaus room thermostat should not 

come into contact with water or excessive humidity. Unless an external 

damage occurs, the room thermostat does not require any maintenance.

Room thermostat should be installed at 1,50 m height from 

ground. 

 

     

  

At least 30 cm distance should be available from doors and 

windows open for air circulation.  

 

 

 

2.3. USE OF OUTSIDE TEMPERATURE SENSOR 

(OPTIONAL)

This product can be used together with a Outside Temperature Sensor 

which can be purchased separately as an accessory.
When connected to a Outside Temperature Sensor, the appliance runs with 

reference to the weater temperature, based on selected heating curve. 

Available heating curves are given in figure 5.

Figure 3 

Thermostat position

150 cm

Min.

30 cm

Figure 4 

Boiler controlled by Outside Temperature Sensor

Figure 5 

Heating curves for Outside Temperature Sensor

20,0

30,0

40,0

50,0

60,0

70,0

80,0

-25

-20

-15

-10

-5

0

5

10

15

20

K=0,75 

K=1,5 

K=2,2 

K=3 

K=4,5 

K=6 

K=9 

C.H. Flo

w T

emper

atur

e °C

Outside Temperature °C

MODE

RESET

+

+

0016_00.W170323

0017_00.W210419

0018_00.W210309

Summary of Contents for Enerwa Plus 2530

Page 1: ...CONDENSING COMBI BOILERS USER MANUAL ENERWA PLUS...

Page 2: ...cluding children with limited mental and sensory capabilities or by persons who do not have enough experience and or knowledge unless they are supervised by a person who is responsible for their safet...

Page 3: ...of On Off Stand by and Summer Winter Modes 8 2 1 3 On Off Stand by Positions 8 2 1 4 Operation in Winter Mode 8 2 1 5 Operation in Summer Mode 9 2 1 6 Shutting off the Boiler 9 2 2 USE WITH ROOM THERM...

Page 4: ...le The maintenance and repairs as the result of failure of the product within the warranty period due to material production and installation errors shall be performed as free of charge without claimi...

Page 5: ...mbar G25 DE II 2L3P Natural Gas 25 mbar G25 NL II 2L3B P Natural Gas 25 mbar G25 NL II 2ELL3B P Natural Gas 20 mbar G25 DE I 3 Buthane Gas 28 30 mbar 37 mbar G30 BE CH CY CZ ES FR GB GR IE IT LT PT S...

Page 6: ...ly at the gas meter or an appropriate emergency control valve Immediately evacuate the place Call the National Gas Emergency Service 0800111999 or in Ireland 1850 20 50 50 Do not make any intervention...

Page 7: ...s in this booklet are strictly followed for safe and economical operation of the boiler Important Notes This appliance must not be operated without the casing correctly fitted and forming an adequate...

Page 8: ...ment change will be activated when radiator symbol rapidly flashes DHW adjustment change will be activated when tap symbol rapidly flashes CH Central Heating DHW Domestic Hot Water When the boiler is...

Page 9: ...een on the screen and LCD screen backlight is turned OFF In this mode you can adjust the Domestic Hot Water temperature between 35 60 C with 7 and 8 numbered buttons LCD screen backlight is turned ON...

Page 10: ...ice installation shall only be performed by the Warmhaus Authorised Service The dual cable required for installation is supplied by the dealer consumer Maintenance and Service Life Warmhaus room therm...

Page 11: ...tor systems to operate at high temperatures as standard P24 Child Protection This feature is disabled as default factory setting 0 Child Protection key lock is enabled when parameter is adjusted to 1...

Page 12: ...ler and check if problem is resolved 5 Call for authorised service E 08 Flame circuit failure False flame signal from combustion or electrode Condensate Syphon blocked Electronic board 1 Call for auth...

Page 13: ...mmunication error Boiler does not work E43 error code flashing on the screen after 1 minute of communication error Opentherm line disconnected 1 Remove energy from boiler and re energize E43 will be r...

Page 14: ...disconnections Gas valve failure 1 Call for authorised service E 88 Fault of electronic gas valve managing circuit Boiler does not work E88 error code flashing on the screen Cabling disconnections Ga...

Page 15: ...ectrode Electrode position Combustion calibration 1 Call for authorised service E 96 Flue or air suction way blockage Boiler does not work E96 error code flashing on the screen Blockage in flue Blocka...

Page 16: ...and also you can acquire approximately 6 power saving with every degree of temperature decrease Ventilation Do not leave windows slightly open for ventilating room rooms In such case continuous heat l...

Page 17: ...relevant European directives Differences to product information listed elsewhere may result in different test conditions Only the data that is contained in this product information is applicable and...

Page 18: ...ion Qfuel kWh 14 809 23 152 23 615 23 078 29 317 Annual fuel consumption AFC GJ 11 18 18 18 23 Condensing boiler Yes Yes Yes Yes Yes Low temperature boiler Yes Yes Yes Yes Yes Combi Boilernation boile...

Page 19: ...19 warmhaus co uk...

Page 20: ...dent s Plant Protection team Cadent provide first line support for our assets Gas Emergencies If you smell gas or have accidentally hit the NTS pipeline please call us urgently 0800 111 999 Electricit...

Reviews: