4.1

Temperature Adjustment

TH131

Use the dial on the front of the thermostat to set the desired tempera-
ture.

NOTE

: If the dial is placed at a temperature beyond the high or low

temperature limit, the temperature will be maintained at that limit (see
section 3.2).
TH133

Remove the control module from the base and use the dial on the
back of the control module to set the desired temperature.

4.2

On/Off Switch (TH131 only)

Use the On/Off switch to turn the thermostat Off when it is not used

(e.g., in the summer).

TH131 accepts the six following pilot wire orders when installed on a

230 V power base.

Setpoint range

: 7°C, 15°C to 35°C (45°F, 59°F to 95°F)

Minimum temperature limit

: 5°C to 25°C (41°F to 77°F)

Maximum temperature limit

: 15°C to 35°C (59°F to 95°F)

Accuracy

: ± 0.2°C (0.36°F)

Storage

: -20°C to 50°C (-4°F to 120°F)

Heating cycle length

: 15 minutes

Software

: Class A

Controller

: Electronic

Size (H/W/D)

:

TH131

: 78.9 x 78.9 x 16.3 mm (3.1 x 3.1 x 0.64 in.)

TH133

: 78.9 x 78.9 x 18 mm (3.1 x 3.1 x 0.71 in.) 

Operation

4.

Pilot Wire Orders (Europe only)

5.

ORDER

SIGNAL

DESCRIPTION

Comfort

No signal Maintain temperature at setpoint

Reduced setpoint

(3.5k setback)

Maintain temperature at 3.5°C below 

setpoint

frost protection

Maintain temperature at 7°C

g

n

it

a

e

h

 

p

o

t

S

ff

O

1k setback

Maintain temperature at 1°C below setpoint

2k setback

Maintain temperature at 2°C below setpoint

Specifications