Feed unit is blocked.
Check the auger is blocked or not.
There is the problem
about the connection
between motor and auger
Check the fasten screw between
auger and motor loose or not.
Or the auger might jump out
C. Regarding to the last
stage
No fuel in the hopper.
Fill the fuel into the hopper.
4. Feeding not properly
A. too much wood pellet
and cannot burned in
time
The level of feeding
speed is too high
Adjust the combustion fan's speed
up
B. The fire is off due to
little wood pellet can be
burned
The level of feeding
speed is too low
Adjust the combustion fan's speed
Down
5 After ignition the power
is off 15min later.
Pellet feeder unit is off or
pellet is too little.
30
˚
C temperature switch
breaks or the connection
wires of switch loose.
Not enough pressure in
the stove
Check the pellet feeder unit and
restart.
Check the connection wires or
change the 30
˚
C temperature
switch.
Adjust the combustion fan's speed
up
6 orange and lazy fire,
piled pellet, carbon on the
glass
Lack of air intake for
burning.
Clean the block in gate bar.
Check the door and window glass
gasket sealed or not.
Check the air intake pipe and
venting pipe blocked or not, and
clean it. Change to the big diameter
pipes if pipes are too long to affect
combustion.
Adjust the combustion fan's speed
up
Call the dealer to reset the program
7 The fire put out and
power is off automatically.
The hopper is empty.
No fuel feed.
The fuel feed is too little.
low temperature switch
(30
˚
C) is wrong.
Set temperature is
reached
Put fuel into the hopper. refer to (2)
Lower the speed of combustion fan
Cool the stove at least 1 hour then
operate again or change the low
temperature switch (30
˚
C).
"ECO" its normal, waiting, after the
temperature is blow set on, it will
automatically switch on again