Trouble Shooting

 

 

Trouble 

Cause 

Shooting 

Table does not 

raise 

1.

 

There is no oil 

in the 
reservoir 

2.

 

Lowering Valve 
(16) or Steel 
Ball (30) or 
Spring (31) is 

not seating 

Replenish the 

reservoir 

Table does not 
remain elevated 

Lowering Valve (16) 
or Steel Ball (30) is 
not sealing 

Flush the Lowering 
Valve or Steel Balls.  
Or replace them 

with a new one.   

Table does not 
lower 

U Packing (71) is worn 
out or Lowering Valve 
(16) is not opened 

Replace U packing 
(8) with a new one.  
Check the function 

of Lowering Rod (8 
or 6).  Fix or replace 
with a new one 

Oil is leaking for 
Lowering Valve 

O Ring (14) is worn 
out 

Replace O ring with a 
new one 

Oil is leaking from 
Cylinder 

Oil seal (34) or U 
packing (71) is worn 

out 

Replace the O sea or 
the U packing with a 

new one.   

 

Summary of Contents for WSP150A

Page 1: ...Manual Hydraulic Lift Trolleys Owner s Manual Warequip Lift Trolleys WSP150A WSP300A WSP500A WSP800A WSP350A ...

Page 2: ...y to achieve desired platform height To lower the table gently squeeze the release lever and stop when desired platform height is achieved When loading and unloading the lift trolley ensure the brake system is locked When moving the lift trolley release the brake system and ensure the table is lowered prior to moving Always check the rated capacity of the lift trolley before operation ...

Page 3: ...elease lever when the trolley is loaded For security ALWAYS use the brake system KEEP foot OFF the brake pedal when lowering table The trolley is ONLY designed for carrying goods NOT allowed to carry passengers Equally load goods on the centre of the table before lifting or lowering To ensure safety when carrying out maintence ALWAYS lock the supports DO NOT enter under this platform unless it is ...

Page 4: ... parts underneath lowering table ALWAYS try to operate on even ground Try to slide loads onto table rather than lifting Use common sense and the correct lift trolleys to reduce load handling injuries ENSURE all operators of this unit are familiar with these instructions ...

Page 5: ...ealing Flush the Lowering Valve or Steel Balls Or replace them with a new one Table does not lower U Packing 71 is worn out or Lowering Valve 16 is not opened Replace U packing 8 with a new one Check the function of Lowering Rod 8 or 6 Fix or replace with a new one Oil is leaking for Lowering Valve O Ring 14 is worn out Replace O ring with a new one Oil is leaking from Cylinder Oil seal 34 or U pa...

Reviews: