warema_890591_alhb_en_v9•2022-09-01
We reserve the right to make technical modifications
4
LL
NN
X1
N
Motor 230V
X2
P
Lokal 230V
X3
X4
Zentral 230V
Central UP 230 V
AC
Central DO
WN
230 V
AC
Netz 230V
MSE Haus- te
chnik
ZL
LL
NN
X1
N
Motor 230V
X2
P
Lokal 230V
X3
X4
Zentral 230V
Netz 230V
LL
NN
X1
N
Motor 230V
X2
P
Lokal 230V
X3
X4
Zentral 230V
Netz 230V
1
1
2
2
3
1
2
3
M 1
~
1
1
2
2
3
3
1
2
3
1
1
2
2
3
3
1
2
3
Gr
oup
Central
Gr
oup
Te
rminal
PE
L1
N
PE
L2
L2
PE
N
N
Plug-and-soc
ke
t connection
MSE Haus- te
chnik
ZL
MSE Haus- te
chnik
ZL
Central UP
Central DO
WN
Supply line (2.Phase)
230V AC
50 Hz / 6 A
(1*)
Motor 1
Legend:
NYM-J 7 x 1,5
NYM-J 5 x 1,5
NYM-J 3 x 1,5
H05RR
-F 4 G 0,75
BK, T
ype W
AREMA
DO
WN
UP
3
M 1
~
Motor 2
M 1
~
BK
BN
BL
GNYE
Group pushbutt
on
(Mot
or 1 + 2)
P
P
Single pushbutt
on
(Mot
or 3)
Motor 3
Supply line 230 V
AC
50 Hz / 6 A
(3*)
F
Supply line 230 V
AC
to
ne
xt MSEs
Connection: Floating contacts of the sun shading contr
ol syst
em/
GA Com
pact
E
P/C
For fur
ther inf
ormation, see
documentation
to
wiring
diagrams "Anschlusspläne"
Ar
t.No:
816 345
Central
L1
- Max. gr
oup siz
e of 30 mot
or contr
ol units, see v
oltage dr
op diagram.
- Central contr
ol line length, see v
oltage dr
op diagram.
- The power line length is limit
ed
by
the
to
tal mo
tor curr
ent. The
maximum number of driv
es per cir
cuit depends on their curr
ent
consumption and the upstr
eam fuse.
- Max. swit
ching capacit
y of the MSE: see "T
echnical data".
- Only pushbutt
ons ma
y be used.
(1*)
When gr
ouping, 7 x 1.5 mm² must be r
out
ed between the MSE!
(2*)
The push butt
on ma
y only be connect
ed
to
"P". The
Te
rminal "P" ma
y
not be looped thr
ough. Don
’t connect 230 V
AC
to
Te
rminal "P".
At
tention!
The line length
to
a group push butt
on or single push butt
on is
max. 25 metres. (3*)
Multiple outside lines (phases) ma
y be used within a single syst
em
if th
ey
ar
e passed thr
ough a shar
ed
ea
rt
h leak
age cir
cuit br
eak
er
.
A max. of 5 driv
es with a rat
ed mot
or curr
ent of 1 A ma
y be
connect
ed
to
a B6A inline cir
cuit br
ea
ke
r.
At
tention!
All circuits must be switched of
f for maintenance
wo
rk
.
(2*)
(3*)
(2*)
BK
BN
BL
GNYE
BK
BN
BL
GNYE
At
tention!
Only one driv
e ma
y be
connect
ed per MSE!
Fig. 5 MSE Haustechnik ZL wiring diagram