2016156_b•en•2020-02-01
We reserve the right to make technical changes
4
KNX SA 8M230 REG
X5
X1
X6
F1
6,3 AT H
L
N
PE
Supply line
230 V AC,
50/60 Hz, 16 A,
3 x 1.5 mm
2
F2
6,3 AT H
F1
6,3 AT H
F2
6,3 AT H
M∼
M∼
Motor 1
sun shading system
Motor 2
sun shading system
1
3
2
BU BK BN GNYE
N
1
3
2
BU BK BN GNYE
PE
N
PE
M∼
Motor 3
sun shading system
1
3
2
BU BK BN GNYE
N
PE
M∼
M∼
Motor 5
sun shading system
Motor 6
sun shading system
1
3
2
BU
BK BN GNYE
N
1
3
2
BU
BK BN GNYE
PE
N
PE
M∼
Motor 7
sun shading system
1
3
2
BU
BK BN GNYE
N
PE
M∼
Motor 8
sun shading system
1
3
2
BU
BK BN GNYE
N
PE
M∼
Motor 4
sun shading system
1
3
2
BU BK BN GNYE
N
PE
KNX
-
KNX+
-
+
-
+
N
ATTENTION:
Only one motor can be connected per
motor terminal set.
If interconnected, the motor will
be damaged!
The total power per fuse must not
exceed 1000 VA.
All motor lines
H05-RR-F 4 G 0.75 black,
type WAREMA
All bus lines
YCYM 2×2×0,8 mm
KNX Bus
KNX Bus
M1.1
M1.2
M2.1
M2.2
X2
L
M3.1
M3.2
M5.1
M5.2
M6.1
M6.2
M7.1
M7.2
M4.1
M4.2
M8.1
M8.2
KNX SA 6M230 REG
X5
X1
X6
F1
6,3 AT H
F2
6,3 AT H
KN
X-
KNX+
N
M1.1
M1.2
M2.1
M2.2
X2
L
M3.1
M3.2
M4.1
M4.2
M5.1
M5.2
M6.1
M6.2
Motor allocation KNX SA 6M230 REG
Fig. 5
Connection example KNX SA 8M230 REG