Deleting an auxiliary channel

You can delete all auxiliary channels learned into the 

receiver if you have committed an error and you want to 

start over again. Note the following example:

1

1

2

Ι

Ι

Ι

2

3

1

2

= Master channel

= Auxiliary channel

Fig. 3 

Auxiliary channels in receiver 1 and 2 are to be deleted.

Carry out the following steps consecutively with the re-

spective master channel:

D

elete all auxiliary chan-

nels in receiver 1:

 Select 

master channel 1, push 

the learn button and hold 

it for at least 20 seconds 

until the external venetian 

blind no longer carries out 

any movement!

End the procedure:

 Se-

lect channel 1 and press 

the UP or DOWN button.

Delete all auxiliary chan-

nels in receiver 2: 

Select 

channel 2, push the learn 

button and hold it for at least 

20 seconds until the external 

venetian blind no longer car-

ries out any movement!

End the procedure:

 Se-

lect master channel 2 and 

push the UP or DOWN 

button.

Aesult:

  All auxiliary channels in receiver 1 and receiver 2 

were deleted.

ITICE

R

 Only one master channel and 15 auxiliary chan-

nels can be learned into each receiver. The 

master channel cannot be deleted but can only 

be overwritten with a new channel. The auxiliary 

channels are not deleted when you learn in a 

new master channel. The weather station can be 

learned in as an auxiliary channel.

1

Ι

 

 

 

1

Ι

 

 

 

2

Ι

 

 

 

2

Ι

 

 

 

Heartbeat function

When a weather station is learned into the device, the 

heartbeat function becomes active. The weather station cy-

clically sends a so-called "heartbeat pulse" to all receivers 

into which the weather station was learned. If the power 

supply of the weather station fails, for example, the station 

does not send a heartbeat. The receiver may also fail to 

receive a heartbeat pulse from a learned weather station 

when the installation situation is unfavourable. If a heart-

beat signal does fail to arrive for 24 h, this is considered 

by the receiver to be a weather station failure and the sun 

shading system is raised for safety reasons. In this phase, 

the sun shading system cannot be operated as usual: 

When it is lowered manually, the movement is stopped 

automatically after approx. 5 seconds. Pressing the button 

again causes the same reaction. The sun shading system 

can be raised as usual. This is a safety function and not 

an error.

IASICHT

V

 

If you force the sun shading system to move 

down by repeatedly activating the DOWN 

button when the weather station has failed, 

the safety functions are not active. The sun 

shading system may become damaged (e.g. 

due to high winds).

Special functions

Manifold special functions are additionally possible in 

WAREMA EWFS. Should you wish further information, your 

specialist dealer will be pleased to give you the applica-

tion brochure.

The W, B and C function buttons

Function button A of the transmitter can be used to switch 

off the sun control temporarily if you additionally use the 

EWFS Weather station in your system. 

Temporary deactivation of the sun control:

n

  Press the A button of the transmitter and hold until the 

sun shading system stops moving. Release the but-

ton again. The sun control is now switched off for 12 

hours. After this period, the sun control is reactivated 

again automatically.

Installation

n

  First switch off the mains supply at the upstream fuse.

n

  Locate the plug-in connector for the electric drive, 

release the safety catch and disconnect the connec-

tor and plug. Next, connect these to the EWFS Plug 

receiver and lock the plug-in connection with the safety 

catch.

n

  The EWFS Plug receiver must not be subjected to di-

rect sunlight. Route the cable in such a way that water 

cannot flow along the cable into the device. The EWFS 

Plug receiver must be mounted securely (jolt-free 

mounting). If several EWFS Plug receivers are in use, 

they must be mounted a minimum distance of 0.5 m 

apart.

n

  When mounting the plug receiver behind a metal 

panel: Mount the plug receiver such that the side of the 

housing with the printed radio waves symbol   faces 

the opening of the panel. This ensures the best possi-

ble radio reception.

Special mounting housings in different colours are avail-

able for protection from the weather and for discrete instal-

lation of the EWFS Plug receiver on the facade.