background image

3

OPERATION INSTRUCTIONS 

WAGATE SLUICE GATES  – MTV, SPS-TL, SPS-TG, SPK-TG, SPM-P-TG, SPM-S-TG  

SAFETY INSTRUCTIONS 

This manual should be read and properly understood before product commissioning. All personnel working with the 

device must be familiar with the safety and warning instructions in this document. 

STANDARDS/DIRECTIVES

 

Our products are designed and manufactured in compliance to recognized standards and directives. This is certified in 

the Declaration of Conformity. 

COMMISSIONING 

Before commissioning the user need to check that the product is free of any damages obtained during transport or 

storage. 

Prior to first use, the user needs to make sure that the steps described in the commissioning part of the manual has been 

followed precisely. If the device is fitted with a third-party actuator, either supplied by the manufacturer or a third party, 

the user needs to make sure that the setup and commissioning for that product is carried out following that device´s 

own specific operation instructions. 

Please note 

that any actuator supplied by the manufacturer will not have been completely commissioned before 

shipping, as the setup of electrical connection and communication interface can only be performed on site. We 

recommend using a trained technician with knowledge of the chosen type of actuator for this task.      

Commissioning is the sole responsibility of the user. The manufacturer cannot be held liable for any consequential 

damage. 

TRANSPORT AND STORAGE 

TRANSPORT 

The device should be kept on its original packaging during the entire transport. The shipment pallet must be kept level 

and securely fastened down. It is not allowed to stack other products on top of the devise during transport. 

The device can only be moved on its original shipment pallet or using at least two of the lifting points on the outside of 

the device (Only applicable to sluice gates too large to be handled by hand). 

Lifting the product using any other method could result in damage to personnel or the device itself. 

Summary of Contents for WAGATE MTV

Page 1: ...INSTALLATION MAINTENANCE PRODUCT GUARANTEE WAGATE SLUICE GATES PLEASE NOTE SERIAL ORDERNUMBER HERE...

Page 2: ...RCHASING A WAPRO PRODUCT FOR FURTHER PRODUCT INFORMATION PLEASE REFER TO WAPRO COM INDEX OPERATION INSTRUCTIONS 3 TRANSPORT AND STORAGE 3 5 MOUNTING 5 7 COMMISSIONING 8 GERERAL OPERATION 9 10 MAINTENA...

Page 3: ...commissioning for that product is carried out following that device s own specific operation instructions Please note that any actuator supplied by the manufacturer will not have been completely commi...

Page 4: ...the label If purchasing spare parts state the size and type of sluice gate SLUICE GATE APPLICATIONS The following table shows the applicable uses of each sluice gate type as well as which types of op...

Page 5: ...E GASKET All sluice gates are supplied with a mounting gasket for sealing against the mounting surface Make sure that this gasket is correctly mounted and has not been damaged during transport ON OFF...

Page 6: ...sely screw in the fasteners Make sure that all bolts thread easily without applying force to the sluice gate 7 Tighten the fasteners evenly using a spiral tightening sequence Torque the fasteners to t...

Page 7: ...to eliminate excessive flexing The brackets should not be placed more than 1 5m apart AMBIENT CONDITIONS The device is rated for use in temperatures between 25 C 40 C If the device is used below freez...

Page 8: ...step in the operation manual specific to the actuator must be completed ELECTRICAL ACTUATOR The device can be equipped with different types of electrical actuators most commonly from the manufacturer...

Page 9: ...until a natural resistance is met The gate opening is fully closed slightly before reaching the end of the gates travel Pressing hard on the handle will not improve gate performance and can lead to p...

Page 10: ...the commissioning steps in the AUMA specific manual supplied with the actuator or get the local branch of AUMA to carry out the commissioning Contact Wapro for further advice LOCAL ELECTRIC OPERATION...

Page 11: ...lfunctions are caused by other equipment To request warranty service the buyer should contact the WaGate dealer where the valve was purchased within a reasonable time after discovering any defects The...

Page 12: ...Rev 1 0 CONTACT WAPRO customerservice wapro com wapro com SE 46 0 454 185 10 DK 45 64 82 40 00 US 1 888 927 8677 UK 44 114 308 0123...

Reviews: