When connecting the machine to operate from pressure less water supplies – always use ad-
ditional fi ltering to secure that impurities are not sucked in. Hose length should be max. 3 meter 
and of minimum ½". 

To meet these requirements, Nilfi sk recommends that you use the original Nilfi sk suction hose 
kit.

The Machine is designed for suction up to 50 cm above water surface. 

•  Position the machine at max. 0.5 meter above water surface. Detach the high pressure hose 

from the outlet.

•  Ensure that the inlet fi lter is in position and attach the suction hose kit, secure tight connec-

tion to the inlet.

•  Turn on the machine, pressing the start/stop switch (1) into position "

I

".

•  Wait until a steady jet exits the outlet.
•  Switch off the machine and attach high pressure hose (4), spray handle, lance and  nozzle.
•  Start the machine again and activate the spray handle.

4.4  Starting the high pressure washer

 IMPORTANT!

 

 

 

Connecting to mains power supply

The voltage and frequency of the machine (see model tag (14)) must match the voltage and 
frequency of the power supply.

 B9 

 

Insert the power plug into power supply socket.

 B10 

 

Turn on the water.

 B11 

 

Release the trigger lock (7a). Remember to unplug, turn off the high pressure washer and 
lock the trigger, when leaving the high pressure washer unattended 

 B12 

 

Activate the trigger of the spray handle and let the water run until all air has  escaped from 
the water hose.

 B13 

 

Turn on the machine, pressing the start/stop switch into position “

I

”. 

 B14 

 

Activate the trigger of the spray handle. When releasing the trigger of the spray  handle, 
the machine automatically stops. The machine will start again when you  reactivate the 
trigger of the spray handle.

5  After using the pressure washer

 

See the pictorial quick reference guide – storing the high pressure washer. 

 

The high pressure washer should be stored in a frost free room! Should the machine by a mis-
take be frozen, it will be necessary to check it for damages.

5.1  Stopping the high pressure washer

 C1 

 

Shut off the water supply and activate the trigger of the spray handle and let the machine 
run until no more water runs out of the nozzle. This will wash out water hose, high pres-
sure hose, spray lance and nozzles.

 C2 

 

Stop the machine, pressing the start/stop switch into position “

0

”. 

 C3 

 

Unplug the machine from the power supply socket and wind up the electrical cable (5) 
and place it on the holder (15).

 C4 

 

Rinse the spray lance, nozzles and the foam sprayer after use.

 C5 

 

Place spray handle, lance, nozzles, foam sprayer and other accessories in the holders on 
the high pressure washer.

I

O

C

Summary of Contents for AQUA 1100

Page 1: ...AQUA 1100 AQUA 1200 128700022 b 10 2013 User Manual...

Page 2: ...Printed in China Copyright 2013 Nilfisk Advance A S Betriebsanleitung 3 17 User Manual 18 31 DE EN...

Page 3: ...ls 26 3 2 Mounting of quick coupling 26 4 Operating your high pressure washer 27 4 1 Connection of high pressure hose 27 4 2 Mounting of spray lance and Click Clean nozzles 27 4 3 Water Connection 27...

Page 4: ...ARNING Inhalation of aerosols can be hazardous to health Where applicable use a device in order to avoid or re duce aerosols production e g a shield covering the nozzle For protection against aerosols...

Page 5: ...fit tings and couplings recommended by Nilfisk Physical sensory or mental conditions This machine can be used by people with reduced physical sensory or mental capabilities or lack of ex perience and...

Page 6: ...backside when transported in or on a vehicle Detergents This machine has been designed for use with clean ing agents supplied or recommended by Nilfisk The use of other cleaning agents or chemicals m...

Page 7: ...cable is used it shall be suitable for outdoor use and the connection has to be kept dry and off the ground Nilfisk recommends use of an extension cable drum when cable extension is needed which keeps...

Page 8: ...be connected to water mains with a max inlet pressure of 1 MPa 10 bars and max 60 C An ordinary garden hose of min 10 m and max 25 m will be suitable for normal operation at 3 bar inlet pressure IMPOR...

Page 9: ...the machine as far away as possible from the object being cleaned Always adjust the distance and thus the pressure of the nozzle to the surface which is to be cleaned to avoid any damage to the surfa...

Page 10: ...sure fluctuates motor busses fuse blows or no wa ter comes out check the trouble shooting diagram in these instructions In case other problems occur please contact your local Nilfisk distributor Recyc...

Page 11: ...trolley handle 15 on the machine A2 Secure the handle by mounting the 2 screws using the enclosed hexagon key 17 Mounting of wheel brackets A3 Place the wheel brackets 18 on the machine A4 Secure the...

Page 12: ...nozzles and the foam sprayer IMPORTANT Before starting the cleaning job check that the machine is in an upright position and placed on an even surface Do not place the machine in high grass 4 3 Water...

Page 13: ...plug turn off the high pressure washer and lock the trigger when leaving the high pressure washer unattended B12 Activate the trigger of the spray handle and let the water run until all air has escape...

Page 14: ...y be used when the nozzle is detached and the ma chine is stopped D2 Stop the machine and disconnect the nozzle Clean the nozzle D3 Flush the nozzle backwards with water Cleaning of machine vents D4 T...

Page 15: ...e Nilfisk organisation with description specification of the fault Repairs not covered by the guarantee conditions will be invoiced I e malfunctions due to Causes menti oned in section Troubleshooting...

Page 16: ...aration of Conformity Declaration of Conformity Product High Pressure Washer Type Wap by Nilfisk AQUA 1100 AQUA 1200 and accessory variants of above mentioned types The design of the unit corresponds...

Page 17: ...A7 A8 A5 A6 A3 A4 A1 A2 2 3 14 14 3 18 19 20 2 I O...

Page 18: ...C3 C5 C4 C3 C2 C1 C1 B14 B13 B11 B12 B10 B9 B2 B1 B8 B6 B7 I O B3 B4 B5 Max 40 C Max 40 C...

Page 19: ...D5 D4 D3 D2 D1...

Page 20: ...lfisk Advance Inc 1 6 6 Kita shinyokohama Kouhoku ku Yokohama 223 0059 Website www nilfisk com MALAYSIA Nilfisk Advance Sdn Bhd Sd 14 Jalan KIP 11 Taman Perindustrian KIP Sri Damansara 52200 Kuala Lum...

Reviews: