3.1

 

Installation note & suggestion 

 

Note: 

During installation and construction, relevant circuits should be disconnected to ensure that all circuits are correct before 

energizing. 

 

►►

Installation Suggestion: 

 

1)

 

For cables, suggest laid 60mm deep, over 50mm, and connector area be bending to avoid water. 

 

2)

 

If the turnstiles install in the outside, suggest installed in concrete deep 100-200mm to avoid natural damaged. 

 

3)

 

All the operation should be done when power off. 

 

4)

 

Wear  the  strong  electric  cable  and  the  weak  electric  cable  are  respectively  with  3/4  "PVC  pipe  and  buried  to  the 

corresponding position with cement. 

5)

 

After adjusting the foundation surface, arrange the equipment in good order. 

 

6)

 

After the hole location is determined, drill the hole and embed the anchor bolt or expansion bolt of M12. 

 

7)

 

Open the case, select one of the equipment as the reference (preferably choose the middle one as the reference), align 

the base bolt hole with the corresponding anchor bolt, and pre-tighten the nut. 

8)

 

Connect the power line and control line according to the wiring diagram, and connect the system protection ground wire. 

 

9)

 

Check the mains wiring according to the wiring diagram, check the power wiring and other wiring of the whole equipment 

are correct, and the power can be adjusted after confirmation. 

10)

 

After completion of the installation, check the connection condition of earth wire, connector assembly for connecting line 

and all moving parts with the device. Make sure the connection is firm in order to prevent failure caused by long time 

operation. If any screw or part is not tightened, please tighten. 

11)

 

After the equipment status check is normal, the following functions can be debugged. 

3. Install Instruction

 

Summary of Contents for BO-DS112

Page 1: ...Tripod BO DS112 Please read and follow the installation instructions before operating the equipment and keep the instructions for future reference or use after debugging User Manual...

Page 2: ...2 2 Tripod turnstile electric control system 5 6 2 3 Operating principle of the system 7 3 Install Instruction 8 3 1 Installation note suggestion 8 9 3 2 Turnstile cable drawing 10 3 3 Turnstile circ...

Page 3: ...s control parts e g RFID Fingerprint and Biometric reader device Unified external electrical interface which can be linked to a variety of card readers and can be remotely controlled and managed by th...

Page 4: ...gure 1 1 4 Technical parameter Item Description Cabinet 304 stainless steel Dimension L1200 W230 H980 mm Weight 50Kg Pass Width 1 lane 550mm Arm length 500mm Power supply AC220V 110V 50 60Hz Working v...

Page 5: ...control board infrared sensor direction indicator board alarm and transformer and so on Card reader self provided after reading the information on the card and judging and processing it will send an...

Page 6: ...board The control center of the system which receives signals from the card reader and infrared sensor and makes logical judgment and processing of these signals and then sends out execution commands...

Page 7: ...ator and motor so that the direction indicator sign turns into the green arrow pass sign At the same time the turnstile sends the setting voice the main control board controls the motor operation and...

Page 8: ...e and embed the anchor bolt or expansion bolt of M12 7 Open the case select one of the equipment as the reference preferably choose the middle one as the reference align the base bolt hole with the co...

Page 9: ...9 Tripod BO DS112 www wano pl Figure 3 Figure 4...

Page 10: ...10 Tripod BO DS112 www wano pl Figure 5 3 2 Turnstile cable drawing Figure 6...

Page 11: ...d wiring diagram Turnstile electrical parts area with power supply port please connect to 110V 220V electrical power supply Turnstile circuit board with port OP L COM OP R it can be connected to any t...

Page 12: ...ohibited 0 R L all prohibited 1 All permitted 2 Left prohibited right permitted 3 Right prohibited left permitted default is 0 F 0 3 Turnstile working mode 0 Free passage 1 Arm down when power off def...

Page 13: ...normally open state If it is a continuous signal the gate will always be open After the continuous signal is disconnected the gate will resume the standard mode The default parameter is 6 seconds tha...

Page 14: ...valve terminal of the main board and judge whether the solenoid valve is damaged B Tripod turnstile arms won t fall down when power off a check if the electromagnet pole drop support is loose readjust...

Page 15: ...pod BO DS112 6 Customer Service 15 We are very happy to help you in the future when you encounter problems or product defects if the use or operation is not clear please timely contact the after sales...

Reviews:

Related manuals for BO-DS112