Vector 2000 Series Installation
Troubleshooting
If the hose fails prematurely, check for:
• Chemical attack. If the hose becomes soft, spongy, or harder
than when originally supplied, chemical attack may be the
problem.
• Improper hose selection for the fluid being pumped.
• Improper roller setting. If flow fluctuates back and forth or up
and down in the discharge line, the rollers may not be adjusted
with equal pressure on the hose.
• See Figure 3. If the hose fails in area A, this may occur from
operating the pump at a discharge pressure higher than the
hose is rated for, or with a closed discharge line. If the hose
fails in area B, this may occur from operating the pump under
a higher vacuum or higher inlet pressure than the hose is rated
for, or with a closed suction line.
• Line system problems — debris, closed valves, or a clogged
or packed line.
• Fluid temperature too high.
• Abrasive material being pumped, or solid size too large.
• Hose connector becomes loose:
- Wrong size connector.
- Suction pressure too high
W0456
DISCHARGE
INLET
A
B
Figure 3
Routine Maintenance
Periodically inspect hose for signs of failure caused by chemical
attack, material fatigue, etc.
Check non-petroleum silicone lubricant on hose, and reapply if
worn off.
Inspect roller bearings for damage, and replace if necessary
(See Parts List, item 11).
Check that all fasteners are properly tightened.