Page 1: ...5 W0192A WANNER ENGINEERING INC 1204 Chestnut Avenue Minneapolis MN 55403 TEL 612 332 5681 FAX 612 332 6937 TOLL FREE FAX US only 800 332 6812 www hydra cell com email sales wannereng com INSTALLATION...
Page 2: ...bar Max Temperature Metallic 250 F 121 C consult factory for temperatures above 160 F 71 C Non Metallic Polypropylene 120 F 49 C Kynar 140 F 60 C Inlet Port H 25 1 1 2 inch NPT G 25 1 1 2 inch BSPT Di...
Page 3: ...G 25 X H G 25 S H G 25 I Gallons Per Minute Liters Per Minute 16 0 20 0 24 0 32 0 36 0 40 0 28 0 44 0 48 0 52 0 56 0 60 0 64 0 68 0 72 0 76 0 80 0 84 0 88 0 4 0 8 0 12 0 0 24 0 0 22 0 20 0 18 0 16 0 1...
Page 4: ...1 10 0 254 5 63 143 1 125 28 58 9 44 240 Oil Drain Outlet H 25 1 NPT G 25 1 BSPT Inlet H 25 1 1 2 NPT G 25 1 1 2 BSPT 3 8 18 NPT Drain Port Oil Fill Cap 0 25 6 4 Keyway 2 00 50 8 x W0203A 3 2 81 3 17...
Page 5: ...nditions where pump oil may exceed 200 F 93 C because of a combination of hot ambient temperatures hot fluid temperature and full horsepower load an oil cooler may be required Location NOTE The number...
Page 6: ...re feed system Install draincocks at any low points of the suction line to permit draining in freezing conditions Provide for permanent or temporary installation of a vacuum gauge to monitor the inlet...
Page 7: ...1500 psi W P rated hose for systems to be operated at 1000 psi gauge pressure Use about 6 ft 1 8 m of flexible hose between the pump and rigid piping to absorb vibration expansion or contraction Supp...
Page 8: ...id may come out of this port when the plug is removed Provide an adequate catch basin for fluid spillage if required Fluid will come out of this port when the pump is started so we recommend that you...
Page 9: ...Do not turn the drive shaft while the oil reservoir is empty Check the inlet pressure or vacuum periodically with a gauge If vacuum at the pump inlet exceeds 7 in Hg 180 mm Hg check the inlet piping s...
Page 10: ...10 G25 991 2400A H G 25 Service Fluid End Models with Non Metallic Pump Head...
Page 11: ...Not included with brass pump heads H G 25 Service Fluid End Models with Metallic Pumping Head 8 10 9 Valve Plate Manifold Brass Stainless Steel Cast Iron Valve Plate Manifold Valve Plate Manifold 10...
Page 12: ...n the same manner as the manifold NOTE Plastic valve plates and manifolds should also be inspected for cracks and replaced if necessary 2 Inspect Valves 11 16 38 The three inlet and three outlet valve...
Page 13: ...medium strength threadlocker to the screw Reinstall the screw the follower 21 and a new O ring 20 Tighten to 18 in lbs 2 0 N m i Repeat the above inspection procedure and replacement if necessary wit...
Page 14: ...the top of the fill port e Replace the oil fill cap and complete installation Method 2 head pressure greater than 2 psi This simple and clean method of priming the Hydra cells requires an inlet head...
Page 15: ...15 G25 991 2400A H G 25 Service Hydraulic End W0197A...
Page 16: ...When you reassemble the hydraulic piston use new plungers 23 They are press fit onto the valve plungers 54 and are generally not reusable 3 Reassemble Pistons a Drop a ball 58 into each opening in the...
Page 17: ...shaft rap the end of the shaft three or four times This will provide about 0 006 in 0 15 mm endplay in the shaft f Apply removable threadlocker to the threads of the three cleaned set screws 24 Screw...
Page 18: ...o o v e s f r o m overpressurization Air leak in suction line strainer or gasket Cracked suction hose Empty supply tank Excessive aeration and turbulence in supply tank Worn and slipping drive belt s...
Page 19: ...seepage Rupture of diaphragm Frozen pump Diapragm screw O ring 18 missing or cracked Worn shaft seal Oil drain piping or fill cap loose Valve plate and manifold bolts loose Premature Failure of Valve...
Page 20: ...Wanner Engineering Inc 1204 Chestnut Avenue Minneapolis Minnesota 55403 This warranty does not cover 1 The electric motors if any which are covered by the separate warranties of the manufacturers of...
Page 21: ...32 6812 www hydra cell com email sales wannereng com IMPORTANT Record your pump model number and serial number here for easy reference Model No Serial No Date of Purchase When ordering parts or making...
Page 22: ...D25 038 2211 Plug 316 SST 1 5 G25 024 2010 Cap Screw socket head M10 x 1 5 x 120 mm 11 6 G25 048 2010 Washer split lock M10 25 7 D25 004 1010 Manifold brass 1 D25 004 1022 Manifold 316 SST 1 D25 004...
Page 23: ...HT SST 6 D25 020 1012 Valve Seat Nitronic 50 6 D25 020 1016 Valve Seat tungsten carbide 6 D25 020 1017 Valve Seat Hastelloy C 6 D25 020 3300 Valve Seat ceramic 6 13 D25 021 1010 Valve 17 7 HT SST sta...
Page 24: ...H25 991 2402B H 25 Hydraulic End with metallic pump head W0197A...
Page 25: ...inder valve 3 K25 043 1010 Cylinder valve Kel Cell 3 56 D25 034 2110 O ring Buna 6 57 D25 041 1010 Washer ball retainer 3 58 D25 015 3010 Ball 1 4 12 59 D25 014 1209 Piston with foot and retainer 3 D2...
Page 26: ...d in Diaphragm Kit 11 Valve Spring Retainers C Celcon H 17 7 PH Stainless Steel M Kynar P Polypropylene T Hastelloy C Y Nylon Zytel X Not included in Diaphragm Kit 6 9 10 11 5 3 2 1 8 4 ORDERING INFOR...