background image

8

 

Safety advisory

Electrical Safety

 

1

DANGER

Protection  for  operating  personnel  and  the  equipment  is  only 
ensured if the power supply is used as specified. Any use other 
than described in this manual will compromise the safety and 
function of the power supply and any connected systems.

There  are  no  user  serviceable  parts  inside  the  enclosure. 
Opening and manipulating the device or making any changes 
is extremely dangerous and is therefore not permitted.

Responsibility for adhering to the local prevailing safety 
regulations lies with the operator.

If faults cannot be remedied, take the power supply out of 
service  and  guard  it  against  unintentional  startup. Tampering 
with and modifying the power supplies is hazardous and is 
therefore not permitted.

Note the following points for use:

• 

Do not permit ambient temperatures which exceed the 
range of 0°C…50°C.

• 

Do not use the power supply if there is visible damage to 
the housing or cable.

• 

The power supply should never be installed in areas 
which are subject to moisture or condensation, unusual 
environmental conditions, continuous vibration or strong 
temperature fluctuations, and do not use outdoors.

• 

Disconnect the power supply from the mains when  
thunderstorms are present or when it will not be used for 
longer periods of time.

• 

Do not pull on the cable to disconnect the power supply 
from the mains.

Summary of Contents for GT-86121-1224-W2E

Page 1: ...Manual Startup and Application Plug in power supplies 24V DC valid for the following model 11021 Power supply 24V 0 5A Euro Release 04 2018...

Page 2: ...m us of any error or misunderstanding you come about so we can identify and eliminate it as soon as possible Carry out your work on or with W T products only to the extent that they are described here...

Page 3: ...ices 5 Warning note concept 5 Qualified personnel 6 Disposal 6 3 Safety instructions 7 General precautions 7 Intended use 7 Installation 7 Electrical Safety 8 EMC 9 4 Function 10 5 Connections 11 Outp...

Page 4: ...he plug in power supply model 11021 which is described in this guide along with its properties and technical data Additional information applications and a complete Declaration of Conformity for the d...

Page 5: ...rious injury if no appropriate safety measures are taken 1 1WARNING Indicates a hazard which can result in death or serious injury if no appropriate safety measures are taken 1 1CAUTION Indicates a ha...

Page 6: ...r the respective task must be followed especially the safety and warning notes included in it Qualified personnel have received training and experience which enable them to recognize risks associated...

Page 7: ...ll Intended use 1 1DANGER The intended use of the power supply is the use in accor dance with the information provided in the manual The power supply may be operated only using the maximum permitted c...

Page 8: ...edied take the power supply out of service and guard it against unintentional startup Tampering with and modifying the power supplies is hazardous and is therefore not permitted Note the following poi...

Page 9: ...power supply from the mains Do not use chemical agents for cleaning Any repair must be performed by authorised specialists only EMC 1 1NOTE The power supply meets the noise immunity limits for IT equ...

Page 10: ...is an 12 Watts switching power supply with an output voltage of 24V DC and a wide input range of 100 240V AC The power supply is compatible with all W T devices and has an operating temperature range...

Page 11: ...wer supply 11021 comes with an integrated not changeable Euro plug for providing the supply voltage Output connector The power supply includes a 5 9 feet long secondary cable with a special connector...

Page 12: ...12 Housing and dimensions 6 Housing and dimensions The dimensions of the plug in power supply 11021 can be seen in the following drawing...

Page 13: ...60 Hz Input current max 0 5A Output voltage 24V DC Tolerance 5 Ripple max 200mVss Rated current 0 5A short circuit protected Mininum load none Withstand voltage In Out 3KV AC Leakage current 0 25mA Op...