28
Technical details Kanda
Technical details
Door
latch
Ba
I/II
Nominal
capacity*
9
kW
Diameter tube for combustion gases
200
mm
Maximum lumber supply in the stove
4
kg
Maximum brown coal supply
-
kg
Volume of the combustion chamber
-
m3
Surface bottom of combustion chamber
-
m2
* a nominal heat of 9 kW is obtained with a chimney draught of 0.12 mbar
Fuel, wood logs, 30 x 10 cm
Maximum
supply
3
pieces
Primary air valve
max.
Secondary air outlet
max.
Fuel burning period
about 1 hour
Flue gas values in accordance with DIN 4705, DIN 18895 part 2
When door is closed
logs
Flue gas quantity
9.3
g/s
Flue gas temperature
265
˚C
Pre-pressure
0.12
mbar
Yield
78.4
%
CO at 13% O2
0.10
%
Particulate matter
-
mg/m3
Certificate Institute 1625. Test standard EN 13229. Test report no. RRF-29 08 1767