1.2 Installation
Fuels
Low smoke, trouble-free operation of the stove and a supply of heat at the nominal
level with a chimney draught of 12 Pa are only guaranteed when you use the fol-
lowing fuels and no others.
Only use natural, dry chopped firewood with a remaining humidity of max. 20%,
and lignite (brown coal) briquettes.
Types of fuels
Heating value appr.
kWh/kg
Hard wood
Soft wood
Wood briquette after DIN 51731
Brown-coal
4,0 – 4,2
4,3 – 4,5
5,0 – 5,2
5,3 – 5,5
With the primary air damper, do you adjust the rated output. There
may be engaged in only the settings and fuel quantities are given that
correspond to your licensed or purchased device.
Adjustment:
Fuel
Setting of the pri-
mary air regulator
Setting of the
fuel selector
Burning
time
8 kW
Warning up,
kindling
III
H
-
Wood
Nominal heating
performance
II
H
ca. 0,75 h
Brown-coal
Nominal heating
performance
III
K
ca. 1 h
Putting out of working
order
I
K
-
Table 2
Filling quantities 8 kW
-Split billet: max. length: 33 cm, max. 3 billets per filling, appr. 1,9 kg
-Lignite briquette: max. 2,2 kg
-Wood briquette after DIN 15731 max: 1,5kg
IT IS NOT ALLOWED to burn waste, fine chipping, bark, wood handled with pre-
ventive chemicals, furthermore paper and cardboard. For kindling please use wood
scrapings or grill starter but never use liquid auxiliaries!
The first kindling
•
At the first fire set-up could be a little smoke, but is not dangerous, normal!
In this time, please ventilate the room carefully!
23