35
120/150 Adapter
Smoke tube end ø120
3. Technical specification
Type
111 60
Nominal performance
5 kW
Heating capacity (m
3
)
-under favorable
-less favorable
-not favorable heating circumstances
according to 18893/TAB2 DIN standard
88
53
34
Flue gas values: fuel:
Flue gas stream:
Flue gas temperature:
Min. blast pressure at nominal performance:
Dust (relating to 13% O
2
)
CO (relating to 13% O
2
)
Efficiency
WOOD / BB7”
5,6 / 5,4 g/s
234 / 320
0
C
12 Pa
< 40 mg/m³
0,09/0,07%
1069 / 825 mg/m
3
82,2 / 79,4 %
Summary of Contents for Club Edition 111 60 MEDIAMANT
Page 10: ...10 B Bild 2 Bild 3 Bild 4 Bild 5 Bild 6 Bild 7 ZU OFFEN A ...
Page 19: ...19 ...
Page 20: ...20 ...
Page 29: ...29 Pic 2 Pic 3 Pic 4 Pic 5 Pic 6 Pic 7 closed open A B Furnace chamber walling ...
Page 46: ...46 Fig 2 Fig 3 Fig 4 Fig 5 Fig 6 Fig 7 fermé ouvert Garniture intérieure A B ...
Page 64: ...64 Fig 2 Fig 3 Fig 4 Fig 5 Fig 6 Fig 7 Chiuso Aperto A B Muratura ...
Page 83: ...83 2 kép 3 kép 4 kép 5 kép 6 kép 7 kép BE KI A B ...
Page 89: ...89 111 60 MEDIAMANT Súly kb 112kg 3 Müszaki adatok 3 1 Méretrajzok ...
Page 91: ......