26
Warning! Upon the first kindling, smoke and unpleasant smell may be
generated. Always ensure the proper ventilation of the room (by opening
windows and doors), and heat the fireplace at maximum rated heating
performance. If with the first heating the maximum temperature is not
reached, the above-mentioned effects may as well arise later on.
•
Before installation pull out the delivery securer off the refractory brick
through the furnace chamber.
Open the door by raising the handle (Picture 11). If the equipment is hot, you can
use insulated gloves. Adjust the primary air regulator (Picture 10), secondary air
regulator and the fuel switch according to the Table 1. Put coal lighter or wood wool
onto the fire grate, followed by wood chips. First insert small pieces of wood, and
then larger ones, light them (Picture 12) and close all the doors again. When the
wood burns quickly, and leaves sufficient glowing embers, put additional fuel on the
fire. Thereafter, adjust the air regulators and the fuel switch according to the Table
1 („Adjustment of the burning air”). The first kindling should be performed “finely”
with little fuel only, so that the parts of the fireplace are adapted to heat. During the
first kindling, the generation of smell is normal and absolutely undangerous.
1.3 Putting out of operation
•
Let the glowing ember burn to ashes and the fire-place get cold.
•
Empty the furnace chamber and the ash bin.
•
Close the doors, and shut off all air regulators (position 0) and the fuel switch
(position K)
1.4 Heating instructions
The fireplace should be operated only with closed furnace chamber door. These
doors may be opened only for kindling, loading or when cleaning the furnace
chamber (otherwise draught problems may occur with other equipment connected
to the same chimney).
Warning!
When opening the furnace chamber door, any incorrect handling or
insufficient draught may induce smoke. Always ensure that the furnace
chamber door may be opened only slowly, first just to a small extent, and
then fully after a few seconds. In addition, if you intend to put additional fuel
into the fire, before the opening of the door only there may be only ember bed
in the burning space, i.e. no flames may be visible.
Led into the burning space in correspondence with the existing conditions, the
secondary air provides for the follow-up burning of the combustible components of
in the burning space. This in fact means smoke and soot-poor burning, which
contributes to the protection of the environment. If you wish to commission the
fireplace in a transitional period, please, please first examine the chimney draught,
as it can be especially weak at high external temperatures. Towards this end, hold
a burning match in the slightly opened feeding door. If the flame is not drawn
significantly by the draught, then a so-called starting fire is to be set first. Towards
Summary of Contents for BULLY
Page 15: ...15 Bild 3 Bild 4 ...
Page 16: ...16 Bild 5 Bild 6 ...
Page 17: ...17 Bild 7 Bild 8 ...
Page 18: ...18 Bild 9 Bild 10 Bild 11 ...
Page 19: ...19 Bild 12 Bild 13 Bild 14 ...
Page 34: ...34 pic 3 pic 4 ...
Page 35: ...35 pic 5 pic 6 ...
Page 36: ...36 pic 7 pic 8 ...
Page 37: ...37 pic 9 pic 10 pic 11 ...
Page 38: ...38 pic 12 pic 13 pic 14 ...
Page 55: ...55 Fig 3 Fig 4 ...
Page 56: ...56 Fig 5 Fig 6 ...
Page 57: ...57 Fig 7 Fig 8 ...
Page 58: ...58 Fig 9 Fig 10 Fig 11 ...
Page 59: ...59 Fig 12 Fig 13 Fig 14 ...
Page 80: ...80 Fig 3 Fig 4 ...
Page 81: ...81 Fig 5 Fig 6 ...
Page 82: ...82 Fig 7 Fig 8 ...
Page 83: ...83 Fig 9 Fig 10 Fig 11 ...
Page 84: ...84 Fig 12 Fig 13 Fig 14 ...
Page 99: ...99 pic 3 kép 2 kép ...
Page 100: ...100 4 kép 5 kép ...
Page 101: ...101 6 kép 7 kép ...
Page 102: ...102 8 kép 7 a kép ...
Page 103: ...103 9 kép 10 kép 11 kép ...
Page 104: ...104 12 kép 13 kép ...
Page 109: ...109 ...
Page 110: ...110 3 2 EK Konformitás nyilatkozat ...
Page 111: ...111 ...