32
1.3 Installation
Fuels
Low smoke, trouble-free operation of the stove and a supply of heat at the nominal
level with a chimney draught of 12 Pa are only guaranteed when you use the follow-
ing fuels and no others.
Only use natural, dry chopped firewood with a remaining humidity of max. 20%, and
lignite (brown coal) briquettes.
Types of fuels
Heating value appr.
kJ/kg
Hard wood
Soft wood
Brown-coal
19.500
15.900
11.500
With the primary air damper, do you adjust the rated output.
There may be engaged in only the settings and fuel quantities are
given that correspond to your licensed or purchased device.
Adjustment:
Fuel
Setting of the primary air regula-
tor “A”
Burning time
6kW
8kW
Warning up,
kindling
-
Wood
Nominal heating
performance
ca. 0,75 h
Brown-coal
Nominal heating
performance
ca. 1 h
Putting out of working
order
-
-
-
Table 2
Filling quantities 6 kW
-Split billet: max. length: 33 cm, max. 2 billets per filling, appr. 1,4 kg
-Lignite briquette: max. 1,6 kg
Filling quantities 8 kW
-Split billet: max. length: 33 cm, max. 3 billets per filling, appr. 1,9 kg
-Lignite briquette: max. 2,2 kg
IT IS NOT ALLOWED to burn waste, fine chipping, bark, wood handled with preven-
tive chemicals, furthermore paper and cardboard. For kindling please use wood
scrapings or grill starter but never use liquid auxiliaries!
The first kindling
•
At the first fire set-up could be a little smoke, but is not dangerous, normal!
Summary of Contents for 113 60 Saphir
Page 11: ...11 Ausmauerung Bild 2 Bild 3 Bild 4 Bild 5 Bild 6 Bild 7...
Page 15: ...15...
Page 17: ...17 Luftanschlu 80 mm aussen...
Page 21: ...21...
Page 22: ...22...
Page 23: ...23...
Page 24: ...24...
Page 25: ...25...
Page 26: ...26...
Page 35: ...35 pic 2 pic 3 pic 4 pic 5 pic 6 pic 7 Furnace chamber walling...