45
4.
Technical data
4.1
Data
4.2
Dimensions
W1-40
screw feet
can raise stove height by +20 mm
The dimension information shown is only for information! We reserve the right to
make changes to the construction if these improve the technical level or the
quality!
Model number
W1 - 40
Nominal heat load
6 kW
Space heating ability in m³ in favourable / less
favourable / unfavourable
conditions according to DIN 18893/TABLE. 2
Short-term heating
Long-term heating
114 / 68 / 46
165 / 95 / 65
Exhaust gas for fuel:
Exhaust gas mass
Exhaust gas connector temperature
Flow pressure at nominal heat load
Particles / dust (based on 13% O2)
CO ( based on 13% O2)
Efficiency
Firewood / Lignite
9,7 / 9,7 g/s
275˚C
12 Pa
≤
40 mg/m³
≤
0,09 %
≥
77 %
A
B
850 (+20)