background image

Flash lighting of the battery state green indicator inside the flash

lens   (4);  during  this   phase  release  the  pressure   from  the  TEST

pushbutton in order to carry out only the SHORT test. 

At the end of the test the red led should turn off indicating the

that the test I s finished.

Device status

Green indicator

Red indicator

Battery charged

3 flashes

On

Battery almost charged

2 flashes

On

Battery almost flat

1 flash

On

Battery needs changing

Off

Off

Long test (GPS check)

The execution of the LONG test allows to check the operation of the GPS

module within your W420 AIS MSLD device and allows to emit an AIS test

message.

Make sure the knob (1) is in the 'TEST' position, then press the

'Test/Activation’ pushbutton (5).

Lighting  of   the   red  indicator   light  inside   the  flash  lens   (4)   and

buzzer tone for about two seconds.

Flash lighting of the battery state green indicator inside the flash

lens   (4);   during   this   phase  keep  the   pressure   on   the   TEST

pushbutton.

After about 10 seconds from pressing the TEST pushbutton the

red led will start flashing slowly (1 flash per second). Release the

pressure from the TEST pushbutton.

Your device will try to obtain the position in the next 5 minutes.

If the position is acquired before five minutes, the flash will start

and an AIS test transmission will be performed as confirmation to

the fix found.

15

Summary of Contents for W420 Rescue-Me

Page 1: ...W420 W420EX Ed 1 1 0 US 3 2016 User s manual...

Page 2: ...Doc Wamblee_W420_Users manual US...

Page 3: ...3...

Page 4: ...4...

Page 5: ...C 15 21 The technical data information and illustrations contained in this manual were believed to be correct at the time of print Wamblee s r l reserve the right to change specifications and other in...

Page 6: ...6 EN...

Page 7: ...o are missing at sea As the owner of this radio device you are advised to Read this manual Activate your W420 W420EX ONLY in the event of an emergency Prepare and check an emergency plan Do not activa...

Page 8: ...rating temperature from 20 C to 55 C Stowage temperature from 30 C to 70 C Battery supply 3 primary LiMnO2 2 3AA batteries CR123 non hazardous Battery replacement 5 year from installation Operations a...

Page 9: ...cket using the mounting bracket and adhesive sticker to fix the antenna The use of the AIS MSLD unit with the antenna around the neck or close to the body dramatically reduce the coverage area and is...

Page 10: ...e manual How to arm your W420 W420EX AIS MSLD To ensure that your device is ready for activation the knob 1 must be set to the ARMED position Press the push button 2 inwards to release the safety lock...

Page 11: ...eeping your W420 W420EX in a waterproof pocket or a zone inaccessible to water will prevent its activation Activation of your W420 W420EX AIS MSLD will be indicated by A red light inside the flash len...

Page 12: ...activate automatically you can proceed with manual activation After checking that the knob 1 is in the ARMED position press the Test Activation push button 5 Once pressed your W420 W420EX device will...

Page 13: ...itioning it to OFF Press the push button 2 inwards to release the safety lock and then continuing to hold the push button down rotate the knob clockwise until the OFF position is reached then release...

Page 14: ...W420EX AIS MSLD does not require special maintenance it is only necessary to make a visual check checking the integrity of the plastic case every time you proceed with a periodic test or if there is a...

Page 15: ...420 AIS MSLD device and allows to emit an AIS test message Make sure the knob 1 is in the TEST position then press the Test Activation pushbutton 5 Lighting of the red indicator light inside the flash...

Page 16: ...ID code The ID code is reported on the external label on the back plane of your W420 W420EX AIS MSLD This code is fixed in the device and cannot be changed by the user Compatibility with AIS Chart pl...

Page 17: ...ee old batteries 8 and replace them with three new ones Make sure they are installed the right way round positive pole facing top of device Press the push button 7 and check the test sequence as descr...

Page 18: ...Shipping Within the delivery of the device remove the internal batteries see Changing the batteries and ship the unit without the batteries using the original container or alternatively a carton after...

Page 19: ...blee products are an aid to recovery only it is the responsibility of the user operator to ensure they are fully conversant with the operation of the equipment and the equipment is kept in full workin...

Page 20: ...Wamblee s r l Via Vittori 19 48018 FAENZA RA ITALY Tel 39 0546 623891 Fax 39 0546 623891 email info wamblee it Made in Italy 20...

Reviews: