background image

INSTALLATION OF THE SLATS

Summary of Contents for AXIO

Page 1: ...pletely and retain for future reference AUTOMATIC SLATTED POOL COVERS MANUFACTURER Safety cover compliant with French NFP 90 308 norm to be installed and used according this mounting user manual SUBME...

Page 2: ...standard NFP 90 308 Please maintain the key while opening and closing the cover and more Importantly remove this key after the cover is closed The quality control of the original parcel must be done...

Page 3: ...width of the pool G 50 cm slat strips 6 slats strip qty depending of the length of the pool H Sandow qty depending of the length of the pool 1 Beam J Duckboardinq qty dependinq of the lenqth of the p...

Page 4: ...Submerged system AXIO...

Page 5: ...SHAFT WITH MASONRY SEPARATION WALL...

Page 6: ...Wall fastening...

Page 7: ...Angle mounting...

Page 8: ...PIT WITH PREFABRICATED SEPARATION WALL IN PVC...

Page 9: ...Wall fastening...

Page 10: ...Angle mounting...

Page 11: ...SETTING UP OF THE AXIS...

Page 12: ...INSTALLATION OF THE BEAM AND GRATINGS...

Page 13: ...rs MS 2 X 10 23 Stainless steel nut MS 4 X 24 Stainless steel stop rinq diameter 30 l X 25 Shaftbearing diameter 30 X 26 Stainless steel pin diameter 8 X 27 Cover of 83 mm PVC slats 28 l ens X Adjusta...

Page 14: ...INSTALLATION OF THE SLATS...

Page 15: ...ABLE COLORS White Sand Blue Light Grey Dark Grey O F Adjustable patented caps Fixed fins Strengthened slat Independant alveolus Cover assembly must be done when the pool is filled with water Make up a...

Page 16: ...ANTI LIFTING DEVICE POSITIONING OF THE ANTI LIFTING LOOPS...

Page 17: ...ELECTRICAL CONNECTION...

Page 18: ...CONTROL UNIT WITH PLC For SIREM motorisations for automatic underwater swimming pool coverings...

Page 19: ...O 15A Varistor Power supply terminal block Motor power cable terminal block Electrolyser terminal block control rev counter sensor BOX DIMENSIONS 235 1 Terminal block details 131 170 Motor direction r...

Page 20: ...ain After the system has been activated the engine can be operated lnitialisation 1 Code activation 3 presses on the key then press OK 2 Indicate the position of the motor 3 4th stage uuu 000 00A 1Jt1...

Page 21: ...closing It also shows the current consumption and the speed of rotation The counter value in closed position around 0 is lower than the counter value in open position between 7000 and 8000 2 A time de...

Page 22: ...R CONTROL SYSTEM The signal from the rev counter sensor does not change its status The motor is powered continuously for 5 minutes The manoeuvre is suspended and the motor is stopped for 20 seconds No...

Page 23: ...liance with Norm NF C15 100 Cover components toolbox hammer drill grinder an electric screwdriver an electrical measurement device We advise you to wear handgloves for the manipulation of sharp compon...

Page 24: ...And always monitor the pool access Depending on the geographical location and the weather conditions your cover will survive the winter if you follow these procedures Clean your cover with a high pre...

Page 25: ...articulation Mechanism is also warranty except for the corrosion 6 Months for the solar batteries 12V solar rolling cover This warranty does not cover Polycarbonate slats deformation due to lack of co...

Page 26: ...to supervise children and not to the entire group present around the pool everyone of them may think that another one is watching Do not leave children without supervision a child can drown in a few...

Page 27: ...danger for your children Drowning happens in a few minutes Please maintain constant vigilance and an active monitoring when children are nearby the pool even if they can swim An adult must always be...

Reviews: