7.5 The pump should not be used in 

thetransferring of toxic or contaminated 

liquid. Service and maintenance will not 

be provided, if the pump application is 

not in compliant with the installation 

and operation procedures. The user 

must take the responsibility for the 

damage.

7.6. If the supply cord is damaged, it must be 

replaced by a special cord or assembly 

available from the manufacturer or its 

service agent.

8. Sound pressure level

Motor

dB(A)

TPK 2T ** -   1

<70

TPK 2T ** -   3

<70

TPK 2T ** -   5

<70

TPK 2T ** -   8

<70

TPK 2T ** - 11

<70

TPK 2T ** - 12

<70

TPK 2T ** - 15

<70

TPK 2T ** - 17

<70

Motor

dB(A)

TPK 4T ** -  1

<70

TPK 4T ** -   3

<70

TPK 4T ** -   5

<70

TPK 4T ** -   7

<70

TPK 4T ** -   8

<70

TPK 4T ** - 10

<70

TPK 4T ** - 11

<70

TPK 4T ** - 12

<70

TPK 4T ** - 15

<70

9. Wiring diagram

Summary of Contents for TPK2T5 -1

Page 1: ...ISO 9001 Certified WALRUS PUMP CO LTD TPK Series Immersible Pump Instruction Manual...

Page 2: ...TPK Series Conform to the following directive 2006 42 EC Machinery directive 2014 35 EU Low voltage directive 2014 30 EU EMC Electromagnetic compatibility directive Refer to the following standards E...

Page 3: ...r 2mm 7 Particle Size 2mm 8 Liquids maximum content of solid particles in suspension 50g m 9 Kinematical Viscosity 32 cst mm s 10 Head 50Hz Up to 70M 60Hz Up to 100M 4 Installation The motor surface t...

Page 4: ...subassembly together to proper position Finally screw the frame bolts tight and put the fan cover back 6 Start Up Before start the pump re verify the following items 6 1 Verify if three phase pump ro...

Page 5: ...e responsibility for the damage 7 6 If the supply cord is damaged it must be replaced by a special cord or assembly available from the manufacturer or its service agent 8 Sound pressure level Motor dB...

Page 6: ...Control circuit malfunction 2 Motor cut out during operation 1 Fuses blown or breakers tripped 2 Overheating relay tripped 3 Control circuit malfunction 4 Pump locked by foreign objects 3 Pump gives...

Page 7: ...TPK4T 5 1 438 180 258 123 99 480 222 258 123 99 TPK4T 3 3 TPK4T 5 3 TPK4T 8 3 TPK4T 19 3 448 180 268 142 111 490 222 268 142 111 553 285 268 142 111 784 516 268 142 111 TPK4T 5 5 TPK4T 8 5 TPK4T 11 5...

Page 8: ...mply with these instructions damage or breakdown caused by fair wear and tear negligence misuse incorrect installation inappropriate chemicals or additives in the water inadequate protection against f...

Reviews: