6. Start-Up

Before starting the pump, make sure 

the following:

6.1 For three phase motors, verify if 

the rotating direction is correct. It 

should be clockwise viewing from 

the motor fan cover end.

6.2 All piping joints are completely 

tight. Leakage in piping may cause 

the pump hydraulic loss.

6.3 The pump is filled with liquid.

6.4 The suction filter is not blocked by 

any foreign objects.

7. Operation and Maintenance

It is dangerous to operate 

the pump against a closed 

discharge outlet because it 

will cause extre-mely high 

liquid flow temperature and 

damage the pump in 20 

minutes.

7.1 Lubrication

The pumped liquid lubricates the 

mechanical seal and shaft 

sleeves. 

7.2 Suction Filter

Always keep suction filter clean 

and make sure it is not blocked by 

impurities.

7.3 Periodic Checks

To ensure regular operation, 

please follow the below-checking 

points: 

7.3.1. Check the amount of liquid 

and operating pressure.

7.3.2. Check there are no leaks on 

piping joints.  

7.3.3. Check the tripping of the 

motor starter. 

7.3.4. Check that all controls are 

functioning normally.

~ 1 ~

TPU Instruction Manual

Before installing your new 

system, please study all 

instructions carefully, as the 

warranty does not cover 

failures caused by incorrect 

installation and operation.

1. Application

1.1 The TPU Series is single-stage 

centrifugal pump designed for 

farm or fishery use.

1.2 The pump can not be used to trans-

fer explosive liquids, such as gaso-

line, diesel oil or similar liquids. It 

is suitable to carry liquids such as 

water, coolant, low viscosity or 

other non-corrosive liquids.

2. Product Code Designation

The pump is named by motor’s output 

power. There are numbers in name-

plate.

3. Operating Limits

1. Ambient Temperature: Max. +40

2. Liquid Temperature range: +4

 ~ 

+40

3. Enclosure Class: IP54 
4. Operating pressure: Max. 3kg/cm² 
5. Inlet Pressure: 0 kg/cm²
6. Kinematical Viscosity: 1 cst 

(mm²/s)

7. Max. Suction depth: 6m
8.Stop and Restarts:

5.4 For your safety, please make sure 

that the wiring is correctly ground-

ed.

5.5 To avoid the possibility of dry 

running, we strongly recommend 

installing dry running protection.

5.6 The pumps must be supplied 

through a Residual Current Device 

(RCD) with a rated residual operat-

ing current not exceeding 30 mA.

5.7 If the supply cord is damaged, it 

must be replaced by the manufac-

turer, authorized service agent, or 

qualified persons in order to avoid 

causing a hazard.

5.8 This pump appliance is not intend-

ed for use by persons (including 

children) with reduced physical, 

sensory or mental capabilities or 

lack of experience and knowledge 

unless they have been given super-

vision or instruction concerning 

use of the pump appliance by a 

person responsible for their 

safety.

5.9 Make electrical connection in 

accordance with connecting 

diagram located inside the 

connection box. The motor current 

must be within the rated amps 

range indicated on nameplate. 

Three phase motor requires a 

magnetic starter for safety.

5.10 For three phase motors, please 

check the correct direction of 

rotation of the pump on the motor 

fan cover. When seen from motor 

fan cover end, the pump should 

rotate clockwise.You can reverse 

the direction of rotation by inter-

changing any two of the incoming 

supply wires.

Output power[kW]

times/hour

Below 2.2

250

TPU    1100

Output Power

Model Type

4. Installation

The pump has hot surface 

on the motor. It must be 

installed so that persons 

cannot  accidentally come 

into contact the hot surface.

4.1 We recommend outlet and inlet 

should stay the same size as the 

original. If you marrow the pipe 

size, it will affect the performance 

of the pump.

4.2 For convenient replace or mainte-

nance, the outlet side must be 

installation valve and union, and 

the inlet side should install union 

too.

4.3 Please shorten the pipe as possi-

ble as well, so that reduce leakage.

4.4 Please install filter at inlet, if there 

is easily inhale Impurities.

4.5 Install the pump in a well-ventilat-

ed and well-drained place.

5. Electrical Connection

5.1 The electrical connection 

should be carried out in 

accordance with local 

regulations. Never make 

any connections unless 

the electricity supply has 

been switched off.

5.2 The electrical hazard 

warning mark is placed 

outside the connection 

box. Be careful.

5.3 The electrical connection should 

be carried out in accordance with 

local regulations. The operating 

voltage and frequency are marked 

on the nameplate. Please make 

sure that these data match your 

job requirement. 

7.4 When pump is not in use for a 

period, it should be drained. For 

start up after long time inactivity 

please check if the impeller and 

mechanical seal are free. If they 

are locked up by sand, rust or 

something else please clean them 

up.

7.5 DO NOT use the pump should not 

be used to transfer toxic or 

contaminated liquids. Please 

carefully follow all instructions in 

the manual as Walrus may refuse 

to accept the contaminated pump 

for servicing.

7.6 If the power supply cord is dam-

aged, it must be replaced by an 

authorized engineer or assembly 

available from the manufacturer or 

service agent.

8. Noise Level

Reviews: