7.  Electrical connection

Warnings:

•  Before installing and plugging the controller into the mains, check that the technical characteristics explained in 

these instructions also correspond to those of the electrical mains and voltage.

•  Always use good quality and appropriate electrical cables to connect the controller to the mains and voltage.

•  The electrical equipment must be checked regularly: Damaged wires and cables must be replaced immediately.

•  Install the controller in ventilated places and away from heat sources, especially if the current load is near the maxi-

mum power.

•  After removing the cover to fix it to the bracket, connect the cables to the terminal strip on the circuit board accor-

ding to the connection diagram.

•  Then carefully close the cover again.

Warning

Danger from electrical voltage!

• 

The safety rules must be observed, see Safety rules for working in and on electrical installations

• 

Prevent water from entering the terminal box.

• 

The electrical connection may only be carried out by suitably qualified persons, for details see table Qualification

Regulations:

• 

Accident prevention regulations VGB, BGV A3, TRBS

• 

DIN VDE 0100, DIN VDE 0105

• 

EN 60730 (Part 1)

• 

Regulations (TAB's) of the local VNB

• 

As well as generally recognised rules of technology.

8.  Connection diagram and function

8.1.  Speed controller WPO 55 5-stage

Select output voltage via front knob:

Position 0 = 0 V 

Position 1-5 = individual speeds

Jumper "LED" (J2)

With the jumper "LED" (J2) you can select whether the illumination of the LED is to be controlled via the

front knob or viah an external contact.

•Jumper J2 in position "INT": front knob in position "0", LED = OFF; front knob in position

"1-5", LED = ON.

•Jumper J2 on position "EXT": If the external contact with the terminals "LED" and "GND"

(terminal CN2) is closed, LED= ON. If the external contact is connected to the terminals

"LED" and "GND" (connector CN ") and is open, LED= OFF.

The LED can be controlled externally by a mechanical contact or also by an open collector

.

Summary of Contents for WPO55

Page 1: ...Potentiometer speed control units Assembly and operating instructions Version 6 1 B14...

Page 2: ...Warranty 4 4 Delivery transport storage 4 5 Description 5 5 1 Speed controller type WPO 55 5 5 2 Speed controller type WPO 5 6 Installation 6 7 Electrical connection 7 8 Connection diagram and functio...

Page 3: ...ditions and requirements of the system manufacturer or system builder Safety devices must not be dismantled bypassed or rendered inoperative The speed controller may only be used if it is in perfect c...

Page 4: ...ort circuit 5 Cover or isolate adjacent live parts Disconnect the device from the power supply and secure it against being switched on again Check that there is no voltage using a two pole voltage tes...

Page 5: ...5 stages by means of a rotary knob It has a switch dry contact for remote ON OFF switching of external devices The potentiometer is suitable for surface mounting IP55 Type Dimensions height x width x...

Page 6: ...Take all static and dynamic loads into account Connect the unit only to permanently laid cables Electrical connection only in accordance with the currently valid VDE and EN guidelines as well as TAB s...

Page 7: ...ectrical installations Prevent water from entering the terminal box The electrical connection may only be carried out by suitably qualified persons for details see table Qualification Regulations Acci...

Page 8: ...ellen Einstellen der Stufen 1 5 8 2 Speed controller WPO infinitely variable Wiring diagram 3 Us supply voltage 0 12 VDC 4 output voltage 0 5 ground 1 2 Dry contact for remote ON OFF connections Cable...

Page 9: ...the national regulations The unit and the transport packaging consist mainly of recyclable raw materials 11 Spare parts Only use original spare parts from Walpol When ordering spare parts state the se...

Page 10: ...10 Place Gelsenkirchen Date 01 012 2021 Maximilian Girnus Managing Director WALPOL GmbH...

Page 11: ...emissions CEI EN 55014 1 Measurement of harmonic current emissions CEI EN 61000 3 2 Detections of voltage fluctuations FLICKER CEI EN 61000 3 3 Application of electrostatic discharge EDS CEI EN 55014...

Page 12: ...ww eu...

Reviews: