24
One three prong twist lock outlet is used to provide 120v power. One four prong twist lock outlet is used to
provide 120/240v power. One three prong and one four prong outlet to provide 120/240v power. Two duplex
outlets for 120v power, protected by 15 amp pop up breakers. Full panel is protected by a 42 amp breaker
and GFCI module. Only R models will be equipped with automatic voltage regulation.
WCS12000 & WCS12000R
30 amp
breaker
42 amp main
breaker
125/250v
6-30R
receptacle
125/250v
14-50R
receptacle
125/250v
L14-30
receptacle
One three prong twist lock outlet is used to provide 120v power. One four prong twist lock outlet is used to
provide 120/240v power. One three prong and one four prong outlet to provide 120/240v power. Two duplex
outlets for 120v power, protected by 15 amp pop up breakers. Full panel is protected by a 50 amp breaker
and GFCI module. Only R models will be equipped with automatic voltage regulation.
WCS14000 & WCS14000R
30 amp
breaker
50 amp main
breaker
125/250v
6-30R
receptacle
125/250v
14-50R
receptacle
125/250v
L14-30
receptacle
Full panel GFCI
module
Full panel GFCI
module
2 x 125v receptacles
(5-20R)
125v L5-30
receptacle
2 x 15 amp pop
up breaker
Ground
terminal
Auto idle
control switch
Voltage meter
AVR / Auto
idle indicator.
AVR on
WCS12000R
only
2 x 125v receptacles
(5-20R)
2 x 15 amp pop
up breaker
125v L5-30
receptacle
Auto idle
control switch
Voltage meter
Ground
terminal
AVR / Auto
idle indicator.
AVR on
WCS14000R
only
Summary of Contents for WHS12000