7
5.5 CONTROLS
Before starting to work, all operators should fa-
miliarize themselves with the location and func-
tion of controls.
. Engine:
Read the engine manufacturers operator's
manual before starting for more detailed
instructions.
a.
Ignition Switch:
This key operated switch controls the
electric power to the engine.
OFF Turn key fully counter-clockwise
to stop the electrical system power
and turn the engine off.
RUN Turn clockwise on detent to the run
position. This is the position
where the engine will continue to
run.
START Turn fully clockwise to the last
spring-loaded detent position to
engage the starter solenoid and
start the engine. Release the key
when the engine starts and it will
return to the RUN position.
b.
Choke:
This push/pull knob controls the position
of the choke. Pull the knob out to close
the choke for starting when the engine
is cold. Push the knob in to open the
choke as the engine warms. Always
push the knob fully in when operating the
machine.
c.
Fuel Shut-Off Valve:
This valve controls the flow of fuel to the
engine. Turn the valve at right angles to
the fuel line to turn the fuel off and parallel
to turn the fuel on.
d.
Starting Rope:
This retracting rope and T-bar is used to
turn the engine over for starting. Grasp
the T-bar firmly and pull the rope sharply
to start the engine.
Fig. 5 ENGINE (typical)
EU5000E
EU7200E
EU6000
a
b
c
a
b
d