Electrical wiring

L2

L1

Mounting the charger

Hot wires
Black + Red

Ground
Green or 
Bare wire

INSTALLATION

INSTALLATION

Hardwired Installation

Hardwired Installation

x2

ø3.5 x 9.5mm  

1.

 Carefully remove your charger from the 

packaging box and hang it from the top of the 
wallplate.

1.

 For 

bottom wiring installation, feed the power 

supply wires through the bottom port with enough 
length to easily connect the wires to the terminals. 

2.

 Replace the two wallplate screws to secure 

your charger to the wallplate. Do not over-tighten.

2.

 Connect the electrical wires according to the 

diagram on the left. 

3.

 Use copper conductors only within the wire 

size range of 10 to 6 AWG (6mm2 to 16mm2).

4.

 Strip 1/2” (12mm) of insulation off each wire, 

insert the wires per the diagram, and tighten each 
connector screw to 11.5in·lbs (1.3N·m)

For 

rear wiring installation, feed the power supply 

wires through the rear port (and through the rubber 
grommet, if not using conduit) with enough length 
to easily connect the wires to the terminals.

NOTE:  If using a conduit connection, pull the 
wiring through before connecting the conduit.

Ensure the electrical panel supports a 208/240V 
dedicated circuit with a new, dedicated two-pole 
circuit breaker, rated for the selected amperage 
(see following section). The voltage between the 
hot wires (L1 and L2) must be 208/240V.

Closing the charger

Torque: 13.3in·lbs (1.5N·m)

Rated current adjustment

4

2

6

24A

16A

40A

30A

20A

50A

Position

Amps

Circuit Breaker Rating

5

3

7

32A

20A 

48A

40A

25A

60A

1

2

3

4

5

6

7

8

9 0

The 

40A and 48A 

versions are set to 
position 

7 by default.

ø

 

T20 

5 x 10mm 

Selecting a switch position 
exceeding the rated current will 
not exceed the rated current.

Current 

selector

1.

 Both the 40A and 48A versions of Pulsar Plus 

can be adjusted from 16A to the maximum rated 
amperage of each model. If you are installing your 
charger on a circuit rated lower than the maximum 
rating for your charger, you can use the current 
selector to manually set a lower maximum current.

2.

 On your charger cover, locate the current 

selector and set the rotary switch to the 
appropriate setting per the chart below.

3.

 When setting your charger’s current lower 

than the max.rating, use the label corresponding 
to your selected current value from the enclosed 
amperage reduction label sheet and affix it over 
the existing label on your charger.

Hardwire installations

CAUTION To reduce the risk of fire, only connect 
your charger to a circuit with a branch circuit 
overcurrent protection of 125% of the selected max 
amperage setting of the device in accordance with 
ANSI/NFPA 70 (US) C22.2 NO 280 13 (Canada).

1.

 Carefully reattach the communications cable 

to your charger cover and close the cover of your 
charger. 

2.

 Insert the four corner screws to secure your 

charger cover. Do not over-tighten.

3.

 Making sure to properly align the bottom 

screw opening, place the cover frame on your 
charger and attach the frame with the screw. 
Do not over-tighten.

Proceed to the instructions for installing the 
holster and operating your charger, pages 16-17.

PULSAR PLUS

Amperage Reduction Label

Input/Output: 
208/240VAC, 60Hz, 16A

Input/Output: 
208/240VAC, 60Hz, 16A

Input/Output: 
208/240VAC, 60Hz, 20A

Input/Output: 
208/240VAC, 60Hz, 24A

Input/Output: 
208/240VAC, 60Hz, 24A

Input/Output: 
208/240VAC, 60Hz, 32A

Input/Output: 
208/240VAC, 60Hz, 32A

Input/Output: 
208/240VAC, 60Hz, 40A

Input/Output: 
208/240VAC, 60Hz,40A

Input/Output: 
208/240VAC, 60Hz, 20A

20A

EV Charger

50A

EV Charger

40A

EV Charger

30A

EV Charger

25A

EV Charger

20A

Save this label sheet for future use.

Wallbox Chargers S.L.

Enclosure Type 3R

PN: PUP1-U-1-5-N-002-A

22ºF to 104ºF (-30ºC to 40ºC)

08/2020 Made in Spain

SN: 123456

UID: abcdefgh

Input/Output: 
208/240VAC, 60Hz, 48A

Summary of Contents for Pulsar Plus

Page 1: ...Installation Guide PULSAR PLUS...

Page 2: ...F G Code Definition Model PUP1 Pulsar Plus NA Cable U 25ft EVC 1 Type 1 Power 5 6 11 5kW 9 6kW Version Custom C 0 G N 002 X Hardwired OCPP Hardwired NEMA 14 50P OCPP Plug in version Black Revision X...

Page 3: ...t is connected to the power supply Install your charger in a sufficiently ventilated location and avoid installation in areas with direct sunlight Do not install your Wallbox charger near flammable ex...

Page 4: ...lying debris risk of eye injury Risk of foot injury Sharp element risk of injurious cuts Ground earth connection required Safety icons FCC Note This equipment has been tested and found to comply with...

Page 5: ...0V Y X Switch off the circuit breaker of the electrical outlet before installing your charger Hardwire Version Ensure you have the correct permits for this electrical installation Remember that the NE...

Page 6: ...correctly installed before connecting your charger See instructions on Page 9 8 20 cm x2 Mounting 3 5 x 9 5mm 1 Remove the tape from the wallplate to detach it from the charger 2 Place the wallplate...

Page 7: ...shown in the diagram on the left 2 Loosen the left cable gland in a counter clockwise direction and pull down on the NEMA cable to release it from your charger Safely store or dispose of the NEMA cabl...

Page 8: ...Plus can be adjusted from 16A to the maximum rated amperage of each model If you are installing your charger on a circuit rated lower than the maximum rating for your charger you can use the current s...

Page 9: ...LLATION Holster NOTE Once you have powered on the connected circuit your charger will be ready to charge your EV To fully access your charger functions and control your charger remotely however you wi...

Page 10: ...nce Contact Wallbox customer service Service 888 787 5780 support wallbox com na service na wallbox com www wallbox com If you are using the myWallbox app and have either locked your charger or set a...

Page 11: ...sonnalis C 0 G N 002 X A c ble int gr OCPP A c ble int gr NEMA 14 50P OCPP Version enfichable Noir R vision X R vision INDEX NP PUP1 U 1 5 C 002 A A B F G D C E NP PUP1 U 1 5 N C 002 A PUP1 U 1 5 C 00...

Page 12: ...u il est connect l alimentation lectrique Installez votre chargeur dans un endroit suffisamment a r et vitez l installation dans des zonesexpos es lalumi redirectedusoleil N installez pas votre charge...

Page 13: ...de blessure au pied l ment pointu risque de coupures pr judiciables Connexion la terre requise Ic nes de s curit Remarque de la FCC Cet quipement a t test et d clar conforme aux limites d un appareil...

Page 14: ...nnement MISE LA TERRE NEUTRE 120 V 120 V 240 V Y X Vous avez ferm le disjoncteur de la prise lectrique avant d installer votre chargeur Version c bl e Assurez vous d avoir les autorisations appropri e...

Page 15: ...s que la prise est hors tension 6 x 45 mm Assurez vous que la prise NEMA est correctement install e avant de connecter votre chargeur Voir les instructions la page 9 8 po 20 cm x2 Montage 3 5 x 9 5 mm...

Page 16: ...de gauche 2 Desserrez le passe c ble gauche dans le sens inverse des aiguilles d une montre et tirez sur le c ble NEMA pour le d gager de votre chargeur Entreposez ou jetez le c ble NEMA en toute s c...

Page 17: ...ouvez utiliser le s lecteur de courant pour r gler manuellement un courant maximal inf rieur 2 Sur le couvercle de votre chargeur localisez le s lecteur de courant et r glez le commutateur rotatif sur...

Page 18: ...ficult s pour connecter votre chargeur votre application myWallbox veuillez consulter le lien Aide et support sur l application sous votre profil utilisateur Si vous rencontrez des probl mes avec l ap...

Page 19: ...halo du DEL est rouge notification d erreur cela signifie que votre chargeur a d tect un probl me de s curit avec votre connexion lectrique ou votre v hicule Compatibilit Mise en charge D pannage 40 A...

Page 20: ...5 6 11 5 KW 9 6 KW Versi n Personalizado C 0 G N 002 X Cableado OCPP Cableado NEMA 14 50P OCPP Versi n enchufable Negro Revisi n X Revisi n NDICE N P PUP1 U 1 5 C 002 A A B F G D C E INICIO Hoja de da...

Page 21: ...ntemente ventilado y evite la instalaci n en reas con luz solar directa No instales tu cargador Wallbox cerca de materiales inflamables explosivos o combustibles Todos los documentos tambi n se pueden...

Page 22: ...culas riesgo de lesiones oculares Riesgo de lesi n en el pie Elemento afilado riesgo de cortes da inos Requiere conexi n a tierra Iconos de seguridad Nota de la FCC Este equipo ha sido probado y cump...

Page 23: ...e antes de instalar tu cargador Versi n cableada Aseg rate de tener los permisos correctos para esta instalaci n el ctrica Recuerda que el tomacorriente NEMA debe colocarse en el lado izquierdo del ca...

Page 24: ...ca de pared con los tornillos de placa de pared provistos No aprietes demasiado Sigue nuestras recomendaciones de ubicaci n y posicionamiento del cargador en la p gina 44 Contin a con las instruccione...

Page 25: ...zquierda 2 Afloja la gl ndula del cable izquierdo en direcci n contraria a las agujas del reloj y tira del cable NEMA hacia abajo para liberarlo del cargador Almacena o desecha de forma segura el cabl...

Page 26: ...ma de cada modelo Si est s instalando tu cargador en un circuito clasificado por debajo de la clasificaci n m xima para tu cargador puedes usar el selector de corriente para establecer manualmente una...

Page 27: ...onectado tu cargador estar listo para cargar tu EV Sin embargo para acceder completamente a las funciones de tu cargador y controlar tu cargador de forma remota deber s descargar la aplicaci n myWallb...

Page 28: ...o con el servicio de atenci n al cliente de Wallbox Servicio 888 787 5780 www wallbox com support wallbox com na service na wallbox com Ten en cuenta que algunos errores iniciar n un reinicio autom ti...

Page 29: ...support wallbox com na V 1 0...

Reviews: