![Wallbox Pulsar Plus Installation Manual Download Page 8](http://html1.mh-extra.com/html/wallbox/pulsar-plus/pulsar-plus_installation-manual_3251049008.webp)
14
15
EN
EN
Electrical wiring
L2
L1
Mounting the charger
Hot wires
Black + Red
Ground
Green or
Bare wire
INSTALLATION
INSTALLATION
Hardwired Installation
Hardwired Installation
x2
ø3.5 x 9.5mm
1.
Carefully remove your charger from the
packaging box and hang it from the top of the
wallplate.
1.
For
bottom wiring installation, feed the power
supply wires through the bottom port with enough
length to easily connect the wires to the terminals.
2.
Replace the two wallplate screws to secure
your charger to the wallplate. Do not over-tighten.
2.
Connect the electrical wires according to the
diagram on the left.
3.
Use copper conductors only within the wire
size range of 10 to 6 AWG (6mm2 to 16mm2).
4.
Strip 1/2” (12mm) of insulation off each wire,
insert the wires per the diagram, and tighten each
connector screw to 11.5in·lbs (1.3N·m)
For
rear wiring installation, feed the power supply
wires through the rear port (and through the rubber
grommet, if not using conduit) with enough length
to easily connect the wires to the terminals.
NOTE: If using a conduit connection, pull the
wiring through before connecting the conduit.
Ensure the electrical panel supports a 208/240V
dedicated circuit with a new, dedicated two-pole
circuit breaker, rated for the selected amperage
(see following section). The voltage between the
hot wires (L1 and L2) must be 208/240V.
Closing the charger
Torque: 13.3in·lbs (1.5N·m)
Rated current adjustment
4
2
6
24A
16A
40A
30A
20A
50A
Position
Amps
Circuit Breaker Rating
5
3
7
32A
20A
48A
40A
25A
60A
1
2
3
4
5
6
7
8
9 0
The
40A and 48A
versions are set to
position
7 by default.
ø
T20
5 x 10mm
Selecting a switch position
exceeding the rated current will
not exceed the rated current.
Current
selector
1.
Both the 40A and 48A versions of Pulsar Plus
can be adjusted from 16A to the maximum rated
amperage of each model. If you are installing your
charger on a circuit rated lower than the maximum
rating for your charger, you can use the current
selector to manually set a lower maximum current.
2.
On your charger cover, locate the current
selector and set the rotary switch to the
appropriate setting per the chart below.
3.
When setting your charger’s current lower
than the max.rating, use the label corresponding
to your selected current value from the enclosed
amperage reduction label sheet and affix it over
the existing label on your charger.
Hardwire installations
CAUTION To reduce the risk of fire, only connect
your charger to a circuit with a branch circuit
overcurrent protection of 125% of the selected max
amperage setting of the device in accordance with
ANSI/NFPA 70 (US) C22.2 NO 280 13 (Canada).
1.
Carefully reattach the communications cable
to your charger cover and close the cover of your
charger.
2.
Insert the four corner screws to secure your
charger cover. Do not over-tighten.
3.
Making sure to properly align the bottom
screw opening, place the cover frame on your
charger and attach the frame with the screw.
Do not over-tighten.
Proceed to the instructions for installing the
holster and operating your charger, pages 16-17.
PULSAR PLUS
Amperage Reduction Label
Input/Output:
208/240VAC, 60Hz, 16A
Input/Output:
208/240VAC, 60Hz, 16A
Input/Output:
208/240VAC, 60Hz, 20A
Input/Output:
208/240VAC, 60Hz, 24A
Input/Output:
208/240VAC, 60Hz, 24A
Input/Output:
208/240VAC, 60Hz, 32A
Input/Output:
208/240VAC, 60Hz, 32A
Input/Output:
208/240VAC, 60Hz, 40A
Input/Output:
208/240VAC, 60Hz,40A
Input/Output:
208/240VAC, 60Hz, 20A
20A
EV Charger
50A
EV Charger
40A
EV Charger
30A
EV Charger
25A
EV Charger
20A
Save this label sheet for future use.
Wallbox Chargers S.L.
Enclosure Type 3R
PN: PUP1-U-1-5-N-002-A
22ºF to 104ºF (-30ºC to 40ºC)
08/2020 Made in Spain
SN: 123456
UID: abcdefgh
Input/Output:
208/240VAC, 60Hz, 48A
Summary of Contents for Pulsar Plus