- 18 -
2070005
System error
Contact service
2080001
System error
Contact service
2080006
System error
Contact service
2080008
System error
Contact service
2080208
System error
Contact service
3000007
Burner temp
sensor
Burner temperature is missing/invalid
Contact service
3010007
Air temp sensor
Air temperature is missing/invalid
Connect air temperature sensor.
3010202
Air overheat
Air temperature is too high
Check air vent´s and warm air hoses for
blockages.
3020007
Water temp
sensor
Water temperature is missing/invalid
Contact service
3020202
Water overheat
Water temperature is too high
Water is not circulate, bleed the air out of
the system, check the waterpump.
50001
System error
CAN bus other errors
Contact service
50006
System error
CAN bus timeout error
Contact service
50008
System error
CAN bus busy error
Contact service
7020B
Low voltage
Cannot start, low voltage
Renew/charge the battery
7020C
System error
Cannot start, device locked
Open locking mode from the control
panel, check control panel user manual.
7020D
System error
Cannot start, enable input not asserted
Enable wire is missing, connect the
enable wire or set the main power ON
7020E
System error
Cannot start, burner temperature
missing or too high
Powercut during the operation, Wait that
unit cools down and try to start again.