Reach Out to a Professional for the Following: 

Glow Failure

Combustion Air Blower Fault

Main Blower Fault

2 s

2 s

2 s

2 s

2 s

Set temperature is higher than the 

cottage temperature - power is increasing

Set temperature is lower than the cottage

temperature - power is decreasing

30 s

30 s

Heating on

Combustion has begun/is running

Low voltage (usually about 15 sec after

initiating start) 

Sun Switch has shut down the unit 

Cooldown/Flameout

Overheat

Locked for security

The device locks itself 

after two unsuccessful starts. 

Reminder indicating there was a fault

after fault code flashed for 5 min 

30 s

30 s

10 s

10 s

In Remote Control Mode

LÄMMITTIMEN VALOT

If the unit has locked itself,
all three lights at the top of
the panel will flash, signaling
there has been a failure that
should be investigated and
resolved prior to further
use. Lights will flash for
about 5 min.

1) While the lights are still
flashing, switch the main
power off from the battery
(Pull power plug, remove the
fuse, open breakers, or in-
line switch). 

2) Wait for 5 sec. and switch
the main power back on.

3) Press Power Button (3)
for more than 3 seconds to
shut down the heater.

4) Restart the heater
normally. 
 

UNLOCKING THE UNIT

The power should never be turned off from the

main switch while the unit is in the cooldown

process after a shut down. 

Don't start the unit while the battery is being

recharged by a generator or a battery charger.

(Risk of over-voltage).

Press the power button to turn the heater off. The

unit cannot be restarted until the cooling phase has

completed.

When heater has cooled down, start it again.

If the heater does not start after two attempts, it

cannot be started again; it will lock down (indicated

by blinking lights on the panel).

Release the lock (instructions on the right).

Depending on the length of the fuel hose, the unit

may have to be started up several times. Keep an

eye on how the fuel travels in the fuel hose while

starting heater.

FIRST IGNITION

After installation or maintenance, if the fuel line is

empty, the heater may not start at the first attempt. If

this is the case, the red combustion indicator light will

start to blink roughly 4.5 minutes after ignition.

 

ITEMS TO NOTE

Heater can be controlled remotely with Wallas 4430A

accessory, which can be purchased separately. 

Heater can be started remotely with a computer or a

mobile device, when the device is installed with a SIM

card with a data package for a network connection. 

Remote control deactivates the Sun Switch. 

REMOTE CONTROL

(ACCESSORY)

See instructional video

to unlock 