Alpha/Delta (Kinetic Operator) Installation and Maintenance Manual
Revision 1 - MAY 2023
145
INSTALLING PHOTOELECTRIC SENSORS FOR EXTERNAL ENTRAPMENT PROTECTION ONLY
Installing Photoelectric Sensors for External Entrapment
Protection Only
Refer to Figure 42 to help plan the most appropriate placement for the photo eyes being installed as
external entrapment protection devices. If no other external entrapment protection devices (like edge
sensors) are installed, then at least two photoelectric sensors are required to guard the gate in each
direction of travel. If the photo eyes are tripped, the operator will temporarily stop the gate.
Consult a photoelectric sensor manual for wiring details. Make all electrical connections to SmartDC
Controller as shown in Figure 43 on the next page.
Operation Notes
• A photo eye trip does not reverse gate.
•
The SmartDC Controller software is factory set to stop upon photo eye trip.
•
Software is configurable to stop and reverse two seconds upon photo eye trip.
If the photo eye is cleared within five seconds, the gate will proceed in the direction of travel.
The SmartDC Controller has three sensor inputs (Sensor 1, Sensor 2, Sensor 3) which can be used for any
type of photoelectric inputs. See
“Figure 43. Connections for Entrapment Protection Only” on page
. Underwriters Laboratories requires that any non-contact sensor used as an external entrapment
protection device, must be tested to, and recognized by, the UL 325 Standard.
There are two common types of photoelectric sensors, thru-beam and retro-reflective, and each has its
advantages.
Figure 42. Photoeye Placement as External Entrapment Protection Devices
Summary of Contents for ALPHA
Page 167: ...Figure 47 Schematic for Kinetic DC 15 Kinetic 1 and Kinetic DC 10F Kinetic 2 Operator s...
Page 168: ......