Installing the Drive on Gate Post
Rev: A
1-7
Establishing the OPEN & CLOSE Limits
The LEARN LIMITS display automatically appears after you set
the gate weight. To set the open and close limits, take the
following steps:
1. Hold the OPEN button until the gate slides to full open.
Release the OPEN button. Note that if you go too far, you
can press CLOSE to reverse direction. Press STOP twice to
store the open stop location in memory.
2. Hold the CLOSE button until the gate slides to full close.
Release the CLOSE button, Press STOP twice to store
the full close location in memory.
Note: Pressing the OPEN button will reverse direction
3. GATE CLOSED appears on the display and ALERT 15
flashes until the target magnet is installed and its location
stored in memory. See
Installing the Target Magnet
.
Figure 1-12
CAUTION
Do not install the target magnet before setting the OPEN and CLOSE limits. If the target
Magnet is installed before setting the limits; the location of sensor hole in beam may be incorrect
and additional holes or repairs to the gate beam may be required to relocate the target magnet.