Page: 5-14
WALKER MANUFACTURING COMPANY
July 2006
SERVICE INSTRUCTIONS
B
A
M
S1
S2
G
10 AMP
CIRCUIT
BREAKER
BATTERY
WALKER MODEL MW
Beginning S/N 2004-68081
S1 = START CIRCUIT
S2 = START/ACCESSORY CIRCUIT
M = MAGNETO GROUND CIRCUIT
B = BATTERY CIRCUIT
A = ACCESSORY CIRCUIT
G = GROUND CIRCUIT
FSC
ACTUATOR
FSC
TOGGLE SWITCH
ENGINE GROUND
RECTIFIER/REGULATOR
MAGNETO
OIL PRESSURE SWITCH
WHT
PUR
BLK
RED
BRN
BLU
BRN/WHT
BRN
RED
GRN
RED
BLK
GRA
BLK
BLK
BLK
BLK/GRA
BLK
BLK/WHT
BLK
GRA/WHT
HOUR METER
RED/YEL
RED/YEL
GRN
OPERATOR
PRESENCE
SWITCH
NEUTRAL
SWITCH
PTO
SWITCH
Wiring Diagram - Model MW
Summary of Contents for MT, MTL, MTEFI, MTLEFI
Page 4: ...WALKER MANUFACTURING COMPANY July 2006 SERVICE INSTRUCTIONS...
Page 102: ...Page 2 48 WALKER MANUFACTURING COMPANY July 2006 SERVICE INSTRUCTIONS...
Page 134: ...Page 3 32 WALKER MANUFACTURING COMPANY July 2006 SERVICE INSTRUCTIONS...
Page 230: ...Page 5 18 WALKER MANUFACTURING COMPANY July 2006 SERVICE INSTRUCTIONS...
Page 252: ...WALKER MANUFACTURING COMPANY Page 7 1 July 2006 SERVICE INSTRUCTIONS SECTION 7 Index...