Section 5:
Electrical Installation
LED Controller Specifications
Ambient temperature
5°C to 50°C (35°F to 122°F)
Input voltage range (115V LED Controller)
115V, 50–60Hz,
Mains supply voltage not to exceed ±10% of nominal
Power Rating 16W (Max)
Input voltage range (230V LED Controller)
230VAC, 50-60Hz,
Mains supply voltage not to exceed 10% of nominal
Power Rating 16W (Max)
Protection class
IP65
A circuit breaker or switch must be installed near the dryer. This should be easy to reach and shall be certified according
to EN60947-1 and EN60947-3. The switch or circuit breaker shall be marked as the disconnecting device for the dryer and
needs to be marked with on and off positions.
Output connections do not provide isolation from the mains connectors and interconnecting wiring must meet EN61010-
1:2001 requirements for reinforced insulation.
PIN
OUTPUT
2
1
PIN
Earth
INPUT
N
L1 (110 VAC or 220 VAC*)
* Unit voltage rating must match supply voltage.
** Supplied from factory with jumper in female DIN
between pins 1 and 2.
1
2
3
1
2
POWER SUPPLY
ENERGY MANAGEMENT / ALARM
INPUT
N.C.
2
1
Energy Management Connections**
Alarm Connections
5VDC (+)
N.O.
3
12-24VDC
Section 5: Electrical Installation
23
PRODRY PD0046 - PD0360 Instruction Manual
|
Walker Filtration
|
Fig ure 5.1 : LED C ontrolle r electrical connections
LED Controller Specifications
Ambient temperature
1.5°C to 50°C (35°F to 122°F)
Max. relative humidity
80% up to 31°C (88°F), decreasing linearly to 50% RH at 50°C (122°F)
Input voltage range (11
5V
LED Controller)
1
15V
, 50–60Hz,
Mains supply voltage not to exceed ±10% of nominal
Power Rating 16W (Max)
Input voltage range (230V LED Controller)
230V
AC, 50-60Hz,
Mains supply voltage not to exceed 10% of nominal
Power Rating 16W (Max)
Protection class
IP65
Transient over voltage
IEC 60664 Class II
Pollution degree
2, IEC 60664
A circuit breaker or switch must be installed near the dryer. This should be easy to reach and shall be certified according to
EN60947-1 and EN60947-3. The switch or circuit breaker shall be marked as the disconn ecting device for the dryer and needs
to be marked with on and positions.
Output connections do not provide isolation from the mains connect ors and interconnecting wiring must meet EN61010-1:2001
requirements for reinforced insulation.
Figure 5.1: LED Controller electrical connections