Specifications
Gas Supply Requirements
- Australia
- New Zealand
- United Kingdom
Category:
II
2H3P
(20, 37).
Flue Type:
A
1.
* - Measure burner operating pressure at manifold test point with two burners operating at full
setting. Operating pressure is ex-factory set, through appliance regulator and is not to be
adjusted, apart from when converting between gases, if required. (Refer to ‘Gas Conversion’
section for details).
Natural Gas
LP Gas (Propane)
Input Rate (N.H.G.C.)
- each Open Burner
28 MJ/hr
28 MJ/hr
Supply Pressure
1.13 - 3.40 kPa
2.75 - 4.50 kPa
Burner Operating Pressure (*)
0.95 kPa
2.6 kPa
Gas Connection
See ‘Gas Connection’ information overleaf.
Natural Gas
LP Gas
Input Rate (N.H.G.C.)
- each Open Burner
28 MJ/hr
28 MJ/hr
Supply Pressure
1.13 - 3.40 kPa
2.75 - 4.50 kPa
Burner Operating Pressure (*)
0.95 kPa
2.6 kPa
Gas Connection
See ‘Gas Connection’ information overleaf.
Natural Gas (G20)
Propane (G31)
Heat Input (nett)
Nominal
6.5 kW
6.5 kW
Reduced
1.75 kW
1.75 kW
Gas Rate (nett)
Nominal
0.69 m
3
/hr 0.51
kg/hr
Reduced
0.19 m
3
/hr 0.14
kg/hr
Supply Pressure
20 mbar
30 / 37 mbar
Burner Operating Pressure (*)
9.5 mbar
26 mbar
Gas Connection
See ‘Gas Connection’ information overleaf.