![Waldorf RN8910G Installation And Operation Manual Download Page 22](http://html1.mh-extra.com/html/waldorf/rn8910g/rn8910g_installation-and-operation-manual_869487022.webp)
20
Gas Conversion and Specifications
Gas Specifications
- Australia:
- New Zealand):
- UK Only:
Category:
II
2H3P
(20, 37).
Flue Type:
A
1.
- (*) Measure burner operating pressure at manifold test point with two burners operating at full setting.
Operating pressure is ex-factory set, through the appliance regulator and is not to be adjusted, apart from
when carrying out Gas Conversion, if required. (Refer to information in this section for details).
Natural Gas
LP Gas (Propane)
Open Burner
Main Burner Injectors
Ø 2.45mm
Ø 1.50mm
Pilot Burner ('PF' Option Only)
0.30 0.20
Oven
Main Burner
Ø 2.60mm
Ø 1.60mm
Pilot Burner
0.35 0.23
Low Fire
Ø 1.5mm
Ø 0.95mm
Burner Aeration Setting
Fully Open
Fully Open
Supply Pressure
1.13 - 3.40 kPa
2.75 - 4.50 kPa
Burner Operating Pressure (*)
0.95 kPa
2.6 kPa
Gas Regulator Cap Screw
Natural Gas
LP Gas
Open Burner
Main Burner Injectors
Ø 2.45mm
Ø 1.50mm
Pilot Burner ('PF' Option Only)
0.30 0.20
Oven
Main Burner
Ø 2.60mm
Ø 1.60mm
Pilot Burner
0.35 0.23
Burner Aeration Setting
Fully Open
Fully Open
Supply Pressure
1.13 - 3.40 kPa
2.75 - 4.50 kPa
Burner Operating Pressure (*)
0.95 kPa
2.6 kPa
Gas Regulator Cap Screw
Low Fire
Ø 1.5mm
Ø 0.95mm
Natural Gas (G20)
Propane (G31)
Open Burner
Main Burner Injectors
Ø 2.30mm
Ø 1.40mm
Pilot Burner ('PF' Option Only)
0.30 0.20
Oven
Main Burner
Ø 2.60mm
Ø 1.60mm
Pilot Burner
0.35 0.23
Low Fire
Ø 1.5mm
Ø 0.95mm
Burner Aeration Setting
Fully Open
Fully Open
Supply Pressure
20 mbar
37 mbar
Burner Operating Pressure (*)
9.5 mbar
26 mbar
Gas Regulator Cap Screw
Summary of Contents for RN8910G
Page 8: ...6 Dimensions RN L 8910G ...
Page 26: ......