Waldorf RN8510G Installation And Operation Manual Download Page 4

Introduction

 

We are confident that you will be delighted with your WALDORF GAS RANGE STATIC OVEN and it will  

become a most valued appliance in your commercial kitchen. 

 

To ensure you receive the utmost benefit from your new Waldorf appliance, there are two important things 

you can do. 

 

Firstly: 

Please read the instruction book carefully and follow directions given.  The time taken will be well spent. 

 

Secondly: 

If you are unsure of any aspect of installation, instructions or performance of your appliance, contact 

your BLUE SEAL dealer promptly.  In many cases a phone call could answer your question. 

 
CE Only: 

These instructions are only valid if the country code appears on the appliance.  If code does not appear 

on appliance, refer to supplier of this appliance to obtain technical instructions for adapting appliance to 

conditions for use in that country. 

 
 
 

G

REAT

 

CARE

 

MUST

 

BE

 

TAKEN

 

BY

 

THE

 

OPERATOR

 

TO

 

USE

 

THE

 

EQUIPMENT

 

SAFELY

 

TO

 

GUARD

 

IT

 

AGAINST

 

RISK

 

OF

 

FIRE



T

HE

 

APPLIANCE

 

MUST

 NOT 

BE

 

LEFT

 

ON

 

UNATTENDED



I

T

 

IS

 

RECOMMENDED

 

THAT

 

A

 

REGULAR

 

INSPECTION

 

IS

 

MADE

 

BY

 

A

 

COMPETENT

 

SERVICE

 

PERSON

 

TO

 

ENSURE

 

CORRECT

 

AND

 

SAFE

 

OPERATION

 

OF

 

YOUR

 

APPLIANCE

 

IS

 

MAINTAINED



DO NOT 

STORE

 

OR

 

USE

 

GASOLINE

 

OR

 

OTHER

 

FLAMMABLE

 

VAPOURS

 

OR

 

LIQUIDS

 

IN

 

THE

 

VICINITY

 

OF

 

THIS

 

OR

 

ANY

 

OTHER

 

APPLIANCE



DO

 

NOT

 

SPRAY

 

AEROSOLS

 

IN

 

THE

 

VICINITY

 

OF

 

THIS

 

APPLIANCE

 

WHILE

 

IT

 

IS

 

IN

 

OPERATION

Warning 

 
 
 



This appliance is for professional use and is only to be used by qualified 
persons. 



Only authorised service persons are to carry out installation, servicing or gas 
conversion operations. 



Components having adjustments protected (e.g. paint sealed) by the 

 

manufacturer should not be adjusted by the user / operator. 



DO NOT operate the appliance without the legs supplied fitted. 

Caution 

 
 

I

MPROPER

 

INSTALLATION

ADJUSTMENT

ALTERATION

SERVICE

 

OR

 

MAINTENANCE

 

CAN

 

CAUSE

 

PROPERTY

  

DAMAGE

INJURY

 

OR

 

DEATH

.  R

EAD

 

THE

 

INSTALLATION

OPERATING

 

AND

 

MAINTENANCE

 

INSTRUCTIONS

  

THOROUGHLY

 

BEFORE

 

INSTALLING

 

OR

 

SERVICING

 

THIS

 

APPLIANCE

Warning 

 
 
 
INSTRUCTIONS

 

TO

 

BE

 

FOLLOWED

 

IN

 

THE

 

EVENT

 

THE

 

USER

 

SMELLS

 

GAS

 

ARE

 

TO

 

BE

 

POSTED

 

IN

 

A

 

PROMINENT

 

LOCATION

.  

THIS

 

INFORMATION

 

SHALL

 

BE

 

OBTAINED

 

BY

 

CONSULTING

 

THE

 

LOCAL

 

GAS

 

SUPPLIER

Warning 

Summary of Contents for RN8510G

Page 1: ... l l a t i o n a n d O p e r a t i o n M a n u a l Series RN8510G RN8610G RN8810G Gas Range Static Oven Date Purchased Serial Number Dealer Service Provider 228681 13 RNL8510G RNL8610G RNL8810G For use in GB IE DK ...

Page 2: ...ares tel 1800 337 963 Customer Service tel 1800 335 315 fax 1800 350 281 CANADA Serve Canada Web www servecanada com E Mail info servecanada com Sales tel 800 551 8795 Toll Free Service tel 800 263 1455 Toll Free NEW ZEALAND Moffat Limited Web www moffat co nz E Mail sales moffat co nz Main Office tel 0800 663328 UNITED KINGDOM Blue Seal Web www blue seal co uk E Mail sales blue seal co uk Sales t...

Page 3: ...allation 8 Installation Requirements Unpacking Location Clearances Assembly Gas Connection Commissioning Operation 11 Operation Guide Description of Controls Open Burners Griddle Lighting the Oven Pilot Burner Lighting the Oven Main Burner Turning the Oven to Stand By Pilot ON Only Oven Shut Down Cleaning and Maintenance 15 General After Each Use Daily Cleaning Weekly Cleaning Periodic Maintenance...

Page 4: ...OT BE LEFT ON UNATTENDED IT IS RECOMMENDED THAT A REGULAR INSPECTION IS MADE BY A COMPETENT SERVICE PERSON TO ENSURE CORRECT AND SAFE OPERATION OF YOUR APPLIANCE IS MAINTAINED DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPOURS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IT IS IN OPERATION Warning This appliance is for...

Page 5: ... RN 1 8819G 2 Gas Range Static Oven 2 Open Burners 900mm Griddle Storage Cabinet NOTE 1 Back Options Standard Models L Low Back Models 2 Open Burner Options F With Flame Failure Protection PF With Pilot and Flame Failure Protection General A heavy duty general purpose gas range created for compact modular kitchens It has a high option Cook Top Griddle arrangement and is available on industrial adj...

Page 6: ... G20 Propane G31 Open Burner each Griddle each 300mm section Oven Open Burner each Griddle each 300mm section Oven Heat Input nett Nominal 6 5 kW 5 5 kW 8 0 kW 6 5 kW 5 5 kW 8 0 kW Reduced 1 75 kW 1 85 kW 2 4 kW 1 75 kW 1 95 kW 2 4 kW Gas Rate nett Nominal 0 69 m3 hr 0 58 m3 hr 0 85 m3 hr 0 51 kg hr 0 43 kg hr 0 62 kg hr Reduced 0 19 m3 hr 0 20 m3 hr 0 25 m3 hr 0 14 kg hr 0 15 kg hr 0 19 kg hr Sup...

Page 7: ...5 Dimensions RN L 8510G Cook Top Options RN L 8510G RN L 8513G ...

Page 8: ...6 Dimensions RN L 8610G Cook Top Options RN L 8610G RN L 8613G RN L 8616G RN L 8619G ...

Page 9: ...7 Dimensions RN L 8810G Cook Top Options RN L 8810G RN L 8813G RN L 8816G RN L 8819G ...

Page 10: ...adjusted by an authorised service agent They are not to be adjusted by the installation person Unpacking Remove all packaging and transit protection from appliance including all protective plastic coating from exterior stainless steel panels Check equipment and parts for damage Report any damage immediately to carrier and distributor Report any deficiencies to distributor who supplied the applianc...

Page 11: ...s Type the appliance has been supplied for is shown on coloured stickers located above gas connection point and on rating plate Check this is correct for gas supply appliance is being installed for Gas conversion procedure is shown in this manual b Supply Pressure required for this appliance is shown in Specifications section of this manual Check gas supply to ensure adequate supply pressure exist...

Page 12: ...e 10 Verify operating pressure remains correct Commissioning 1 Before leaving new installation a Check following functions in accordance with operating instructions specified in Operation section of this manual Lighting the Griddle Lighting the Open Burners F Flame Failure Option Lighting the Open Burners PF Pilot and Flame Failure Option Check the Low Fire burner operation Light the Oven Pilot an...

Page 13: ...ning the Oven to Stand By Mode Oven Shut Down Description of Controls Griddle Option Burner Control OFF Position PILOT Burner HIGH Flame LOW Flame Gas Control Knobs Piezo Igniter Griddles Only Piezo Igniter Oven Oven Option OFF Position PILOT Burner Temperature Graduations 100 C to 290 C Open Burner Option OFF Position HIGH Flame LOW Flame Rear Burner Front Burner Indicators are located above the ...

Page 14: ...ned ON OFF without having to manually re light burner each time that it is turned ON as burner will automatically light itself off pilot burner Flame Failure Protection is incorporated for each burner by way of a thermo electric system which will shut off gas supply to that burner in event that burner goes out so that un burnt gas is not expelled a Select burner required depress and turn correspon...

Page 15: ...h is incorporated by way of a thermo electric system for the main burner Flame failure protection will shut off gas supply to burner in the event that pilot burner goes out so that un burnt gas is not expelled This is an important safety feature which is slowly becoming law throughout the world 1 Open oven door Partially depress thermostat control knob whilst turning anti clockwise to Pilot positi...

Page 16: ...amaged 1 To turn Off oven completely partially depress thermostat control knob whilst turning clockwise to O Off position pilot burner will extinguish DO NOT fully depress Thermostat Control Knob whilst trying to rotate clockwise to Off position as Knob and Gas Valve will be damaged Control Knob in Main Burner Operating Position Rotate Knob Anti Clockwise to Operating Temperature Control Knob in P...

Page 17: ...detergent or cleaning material has been completely removed after each cleaning Appliance should be switched On briefly to ensure griddle plates become dry Oil or grease should be spread over griddle surface in order to form a thin protective greasy film To keep your range clean and operating at peak efficiency follow procedures shown below After Each Use 1 Clean griddle with a scraper tool to remo...

Page 18: ...ce is cold and rub in direction of grain c It should not be necessary to remove splash guards covering burner manifolds for cleaning purposes These can be cleaned in situ d Remove grease tray and clean with a mild anti bacterial detergent and hot water solution using a soft bristled brush Clean control panel with a damp cloth moistened with a solution of mild detergent and water e Dry the grease t...

Page 19: ...ean interior and exterior surfaces of range with hot water a mild detergent solution and a soft scrubbing brush Note that gas control knobs are a push fit onto gas control valve spindles and can be removed to allow cleaning of front control panel b Baked on deposits or discolouration may require a good quality stainless steel cleaner or stainless steel wool Always apply cleaner when appliance is c...

Page 20: ...pill cover d Dry oven thoroughly with a dry cloth and polish with a soft dry cloth Periodic Maintenance NOTE All maintenance operations should only be carried out by a qualified service person To achieve the best results cleaning must be regular and thorough and all controls and mechanical parts should be checked and adjusted periodically by a qualified service person If any small faults occur hav...

Page 21: ...Gas pressure too low Partially blocked pilot injector Thermocouple connection to gas control is loose or faulty Thermocouple faulty Electromagnet in rear of gas control unit is faulty Hold knob in for at least 20 seconds following ignition of pilot Clean or replace pilot injector Tighten thermocouple connection Check thermo couple is producing between 20 30mV Inspect and replace if not in good wor...

Page 22: ...pports pilot shields PF options only splash guards 2 Remove injectors and replace with correct size injectors as shown in Gas Specifications Tables at end of this section For F Options Only Unscrew and remove main injectors For PF Options Only Unscrew and remove main injectors and pilot injectors 3 Refit the following Splash guards pilot shields PF options only Trivet supports trivets burner caps ...

Page 23: ...replace with correct size injectors as shown in Gas Specifications Tables at end of this section 4 Refit the following Re connect pilot supply tube to pilot burner Re connect piezo igniter to mounting bracket Refit main burner gas control heat shield and griddle plate to cooktop 5 Re light main burners and check flame size on Low flame position Adjust low fire adjustment screw on open burner gas c...

Page 24: ...unting bracket Refit main burner and sole plate s 5 To Replace the low fire screw in the gas valve Remove the oven control panel Remove low fire screw from gas valve and replace with correct size low fire screw as shown in Gas Specifications Tables at end of this section NOTE The Low Fire Screw should be sealed with coloured paint on completion of low fire adjustment Refit the oven control panel G...

Page 25: ...s DO NOT USE A NAKED FLAME TO CHECK FOR GAS LEAKAGES Warning Natural Gas LP Gas Propane Open Burner Main Burner Injectors Ø 2 45 mm Ø 1 50 mm Pilot Burner PF Option Only 0 30 0 20 Griddle Main Burner Ø 2 10 mm Ø 1 30 mm Pilot Burner 0 35 0 23 Main Burner Ø 2 60 mm Ø 1 60 mm Pilot Burner 0 35 0 23 Low Fire Ø 1 5 mm Ø 0 95 mm Supply Pressure 1 13 3 40 kPa 2 75 4 50 kPa Operating Pressure 0 95 kPa 2 ...

Page 26: ... with Flame Failure 227384 Knob Open Burner with Pilot Flame Failure 228167 Thermocouple 320 mm Front 228166 Thermocouple 600 mm Rear Griddle 014105 Burner 032210 Injector Nat Gas Ø 2 10mm 032130 Injector LP Gas Propane Ø 1 30mm 227403 Gas Control with Pilot Flame Failure 227384 Knob Griddle 019215K Pilot Burner Kit 026488 Pilot Injector Nat Gas 0 35 019217 Pilot Injector LP Gas Propane 0 23 01942...

Page 27: ...LH 228106 Oven Rack RN8510G 227896 Oven Rack RN8610G RN8810G General 227015 Pot Stand Trivet 228884 Spill Tray 750mm RN8510G Series 228883 Spill Tray 450mm RN8610G Series 228882 Spill Tray 600mm RN8810G Series 229674 Rear Roller Assy 227850 Adjustable Leg 150mm Gas Conversion Kits Accessories 228566 Griddle Scraper Tool 228567 Smooth Plate Scraper Blades Pack of 5 blades 228797 750mm Plinth Kit 22...

Page 28: ......

Reviews: