background image

9

SPECIFICATIONS

7

Tips & Tricks

Use a loop or other rythmnic source and connect the

RMS/Peak

output

with a filter or gate input. The detector signal works like an envelope
follower.

Connect a steady tone to the

Main

input and feed a drumloop for exam-

ple to the

Side

input. Now the steady tone should be modulated by the

rhythmic source depending on your

Balance

level.

8

Troubleshooting

8.1

Modules Power Fail

Check the orientation of the pin headers on your modules

Check if the total power consumption of your modules does not exceed
the specifications of your case/frame power supply

9

Specifications

Power Supply:

+12V/110mA, -12V/100mA

Width:

20HP, 101.6mm

Height:

3U, 133.3mm

Depth:

25mm

Total Weight:

350g

Technical specifications and design are subject to change without notice.

10

Summary of Contents for CMP1

Page 1: ...WALDORF CMP1 USER MANUAL Waldorf Music GmbH 2016 11 15 1...

Page 2: ...mbH extends no liabilities in regard to this manual other than those required by local law This manual or any portion of it may not be reproduced in any form without the manufacturer s written consent...

Page 3: ...the device in extremely dusty or dirty environments in order to preserve the device s surface finish Ensure that adequate ventilation is available for the device to cool down Do not place the device n...

Page 4: ...soft cloth or brush to clean the device surface Never use cleaning chemicals as they will damage the device surface 3 Package Contents The cmp1 package contains the following parts cmp1 Compressor Mo...

Page 5: ...the compressor threshold 4 Comp CV Input Used to control the compression ratio 5 Level Input Used to control the signal level by a Control Voltage Classic VCA instead of compression mode 6 Link Input...

Page 6: ...ressor module It s time to integrate it in your modular system 5 1 Power Connection The first step is to supply your module with power The module only requires regulated 12V and 12V voltages These vol...

Page 7: ...is VCA based using the same components you find otherwise in high end analogue compressors Additional features like the output of the detection signal CV control of compressor ratio and threshold and...

Page 8: ...obs will act as attenuators of the CV inputs 6 4 Attack and Release When the detected level reaches above threshold then compression starts in general as already described and ends when the level fall...

Page 9: ...manually gain is always required when threshold or compression ratio changes largely In addition to the compressed signal the Bleed knob can be opened to add uncompressed original signal to the output...

Page 10: ...ne should be modulated by the rhythmic source depending on your Balance level 8 Troubleshooting 8 1 Modules Power Fail Check the orientation of the pin headers on your modules Check if the total power...

Page 11: ...10 BLOCK DIAGRAM 10 Block Diagram 11...

Reviews: