background image

22 

 

Summary of Contents for BP8080E

Page 1: ...a t i o n a n d O p e r a t i o n M a n u a l Electric Bratt Pan BP8080E BPL8080E BP8080EE BPL8080EE BP8120E BPL8120E BP8120EE BPL8120EE Date Purchased Serial Number Dealer Service Provider 228687 11 For use in GB IE ...

Page 2: ...661 0257 Fax 336 661 9546 CANADA Serve Canada 22 Ashwarren Road Downview Ontario M3J1Z5 Toll Free 800 263 1455 Ph 416 631 0601 Fax 416 631 0315 info servecanada com www servecanada com www moffat com NEW ZEALAND Christchurch Auckland Moffat Limited Moffat Limited PO Box 10 001 4 Waipuna Road 16 Osborne Street Mt Wellington Christchurch Auckland Ph 03 389 1007 Ph 09 574 3150 Fax 03 389 1276 Fax 09 ...

Page 3: ...ctrical Connection Water Supply Requirements Dimensions Installation 9 Installation Requirements Unpacking Location Clearances Assembly Electrical Connection Water Connection Commissioning Operation 12 Operation Guide Description of Controls Turning On the Main Element and Setting the Desired Temperature Water Tilting the Pan Turning Off the Main Element Cleaning and Maintenance 15 General After E...

Page 4: ...ALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE INJURY OR DEATH READ THE INSTALLATION OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS APPLIANCE WARNING GREAT CARE MUST BE TAKEN BY THE OPERATOR TO USE THE EQUIPMENT SAFELY TO GUARD IT AGAINST RISK OF FIRE THE APPLIANCE MUST NOT BE LEFT ON UNATTENDED IT IS RECOMMENDED THAT A REGULA...

Page 5: ... electrical BP8120EE models operated tilting mechanism with burner cut out when the pan is tilted Electrical Supply Requirements BP8080E EE 12kW 400 415V ac 50 60Hz 3P N E 12 0 kW 415 V Phase loading L1 16 4 A L2 16 4 A L3 16 4 A BP8120 E EE 17kW 400 415V ac 50 60Hz 3P N E 17 0 kW 415 V Phase loading L1 23 2 A L2 23 2 A L3 23 2 A Electrical Connection When connecting a Waldorf electric appliance t...

Page 6: ...Requirements Cold water connection is 1 2 tube connection via 15 mm crox fitting located 280 mm from the LH side 575 mm from rear and 241 mm from the floor The water supply must be protected by an In Line sediment filter strainer which should be fitted into the pipeline prior to the Bratt Pan water connection Maximum water supply pressure 550kPa 80psi Maximum water inlet temperature 80 C Specifica...

Page 7: ...5 Specifications Dimensions BP L 8080E Model Only ...

Page 8: ...6 Specifications Dimensions BP L 8080EE Model Only ...

Page 9: ...7 Specifications Dimensions BP L 8120E Model Only ...

Page 10: ...8 Specifications Dimensions BP L 8120EE Model Only ...

Page 11: ...re only to be adjusted by an authorised service agent They are not to be adjusted by the installation person Unpacking 1 Remove all packaging and transit protection from the appliance including all protective plastic coating from the exterior stainless steel panels 2 Check equipment and parts for damage Report any damage immediately to the carrier and distributor 3 Report any deficiencies to the d...

Page 12: ...te attached to the lower front hand side of the front sill panel 2 The supply terminal connections are located at the rear of the the appliance Refer to Electrical Connections in the Specifications section of the manual 3 Refer to the appropriate wiring standards for the size of cable that is to be used for the current drawn on that line 4 When connecting a Waldorf electric appliance to the main s...

Page 13: ...s manual Ensure that all water pipework has been thoroughly flushed through prior to using the appliance Check the current draw and loading for the equipment Refer specification section for correct electrical requirements Check that all the connections are correct and that all cover panels have been re fitted Check that the appliance functions in accordance with the operating instructions Ensure t...

Page 14: ... Water Supply Valve Tilting the Pan Turning Off the Main Element Description of Controls BP8080E and BP8120E Models Water Flow Control Valve OFF Position Graduated Flow Temperature Control Knob Graduations from 1 to 10 for heat control Manual Tilt Handwheel Power Indicator Lamp Green Heating Indicator Lamp Amber Fig 3 CAUTION The pan lid and the ends of its handle close to the lid can become hot d...

Page 15: ...OFF Position Graduated Flow Temperature Control Knob Graduations from 1 to 10 for heat control Electrical Tilt Controls With the bratt pan lid open the bratt pan can be electrically raised to the UP position Power Indicator Lamp Green Heating Indicator Lamp Amber Fig 4 ...

Page 16: ...ti clockwise is FULLY open Tilting the Pan BP8080E and BP8120E Models a To tilt the pan turn the pan tilt handle clockwise The heating element will automatically switch Off when the pan is raised b With the pan returned to its down lowered the heating element will turn back On BP8080EE and BP8120EE Models a To tilt the pan up or down depress the pan tilt control switches on the front panel with th...

Page 17: ...ater solution using soft cloth or a soft bristled brush Dry the appliance thoroughly using a dry clean cloth Clean the exterior of the bratt pan using a mild detergent and a hot water solution using soft cloth or a soft bristled brush Daily Cleaning Clean the bratt pan control panel of the using a soft cloth moistened with a solution of mild detergent and hot water DO NOT USE EXCESSIVE WATER Dry t...

Page 18: ...he interior and exterior surfaces of the bratt pan with hot water a mild detergent solution and a soft scrubbing brush Note that the control knobs are a push fit onto the thermostat and water control valve spindles and can be removed to allow cleaning of the front of the control panel b Baked on deposits or discolouration may require a good quality stainless steel cleaner or stainless steel wool A...

Page 19: ... when the pan is in the down position and when the control thermostat is turned ON With the pan in the down position control thermostat turned ON and main water supply ON check that the solenoid valve has electrical power across its coil terminals a If solenoid coil has power but no water available on turning the manual valve check the coil for open circuit short circuit and for solenoid coil burn...

Page 20: ...R 227963 EARTH STUD 1 3 5 13 2 4 6 14 A1 A2 BF18 CONTACTOR OVERTEMP 025400 19 PAN 5 COM NC NO WATER MICROSWITCH 003004 COM NO NC 3 3 3 2 2 2 WATER SOLENOID 020851 EARTH STUD 15 5 16 231739 231739 2 1 10 21 3 3 3 23 20 19 8 8 6 7 6 11 9 12 12 21 10 16 17 14 23 22 24 24 HEAT SAFETY 4 4 L3 L2 L1 GND N OPEN SIDE THIS WAY 22 15 1 1 1 BXF 79 240 SUPPRESSOR 231746 17 ...

Page 21: ...ITCH 003004 COM NO NC 3 3 3 2 2 2 WATER SOLENOID 020851 EARTH STUD 22 5 23 231739 231739 N C N O MOTOR TERMINATION BOX WIRING DETAIL N O N C PAN UP MICROSWITCH 024802 LH COVER PANEL E Motor WHITE RED BLUE GREEN U2 W2 V2 RED BLUE WHITE GREEN 19 16 15 18 6 14 25 COM NC NO 32 34 14 17 TERMINAL BLOCK 025950 1 2 24 11 29 3 3 3 31 28 27 9 9 7 8 7 10 12 13 13 29 11 23 24 17 20 31 30 32 34 33 33 HEAT SAFE...

Page 22: ...7848 Lid Handle 900 mm Wide 228849 Lid Handle 1200 mm Wide 228716 Lid Hinge Spring Kit 227521 Tensioner Barrel 228822 Thermostat Control Knob 227387 Water Control Knob 227857 Electric Motor 900mm 1200 mm EE Models Only 020043 Bearing Housing 228123 Handwheel 228117 Handwheel Spacer Bush N044400 Key Woodruff 7 8 x 5 32 044066 Handle Nut M16 x 2 227850 Leg Assembly Accessories 228798 Plinth Kit 900 ...

Page 23: ...21 ...

Page 24: ...22 ...