![Waldmann MLD Instructions For Use Manual Download Page 18](http://html1.mh-extra.com/html/waldmann/mld/mld_instructions-for-use-manual_869314018.webp)
18
Operation
ENG
4.2 Connecting the luminaire
to the 24 V supply voltage
(SELV)
NOTICE
Material damage caused by wrong
mains voltage.
Damage or destruction of the luminaire.
X
The connection must be made by a
trained skilled electrician only.
X
Compare the mains voltage with
the nominal voltage and the fre-
quency specified on the rating
plate and make sure that they are
identical.
X
Operate the luminaire at safety
extra low voltage (SELV) only.
X
USA and Canada:
This device
must be connected to a class 2
power supply!
1
3
2
No. Designation
1
DC +
2
DC -
3
Not connected
Tab. 1: Pin assignment.
NOTE:
Please observe the pin assignment.
X
Plug the plug into the socket provided
for this purpose.
5. Operation
Fig. 6: Switch.
5.1 Switchon and switchoff
X
Press the switch, see Fig. 6.
5.2 Dimming
X
Press the switch and keep it depressed,
see Fig. 6.
After about one second, the light will
change its brightness.
X
To change the dimming direction, press
the switch again and keep it depressed.
This will save the set brightness. The
next time the light is switched on, the
brightness saved last will be set.