27
Connection
ENG
X
For the pin assignment, please refer to
the following table.
3
1
4
2
5
No. Designation
1
DC +
2
Not used
3
DC −
4
Not used
5
Not used
Tab. 3: Plug M12-A-5, pin assignment type A.
X
Connect a suitable socket to the
A-coded plug.
X
Tighten the union nut of the plug-in con-
nection without twisting the plug and
the socket against each other. Torque:
0.6–2.0 Nm
4.2 Connecting the device to the
luminaire
To connect the device to a luminaire, con-
necting cables are recommended found in
the Waldmann range of accessories.
4
2
3
1
5
No. Designation
1
DC +
2
Bit 0
3
DC −
4
Bit 1
5
Bit 2
Tab. 4: Socket M12-A-5, socket assignment
type E.
X
Connect the device to the luminaire
with a suitable connecting cable.
X
Tighten the union nut of the plug-in con-
nection without twisting the plug and
the socket against each other. Torque:
0.6–2.0 Nm
NOTE:
In luminaires with through-wiring
connected in series, the total current con-
sumption must not exceed
3 A
. The data
given on the rating plate of the device and
the luminaire apply.
NOTE:
The device can only control linked
luminaires of the same model.
X
To link additional luminaires, follow the
instructions for through-wiring in the
instructions for use of the luminaire.